In toggle mode, the <strong>PEL</strong> input alternates between two user-defined input levels. Unlike transient-continuous<br />

mode, the input only changes from one level to another, one transition at a time.<br />

Transient<br />

Level<br />

Main<br />

Level<br />

Toggle<br />

t<br />

Typical Application: Testing the transient recovery time for a CV power supply. The recovery time for a<br />

power supply is defined as the time required for the supply to settle to a predefined settling band following a<br />

change in load current caused by an induced transient (pulse).<br />

LCL Operation:<br />

• From keypad select operating mode (CC, CV, CR, CP)<br />

• Select transient operation for toggle mode.<br />

• Set MAIN and TRANSIENT levels by pressing the “MAIN” and “TRANS” keys.<br />

• To begin the toggle operation, turn on the input and press the “TR ON/OFF. The LCD will<br />

display a flashing “TG” to indicate that the <strong>PEL</strong> is in toggle mode.<br />

All the operating modes can be programmed via the front panel or by way of the GPIB/RS232 Interface.<br />

In addition, each transient can be triggered through an external TTL compatible signal.<br />