Prozess data transmission PZD<br />
Operation manual<br />
8<br />
8 Prozess data transmission PZD<br />
8.1 Parameter process data object (PPO)<br />
The 5 th generation of STÖBER inverters offer various telegram types in the GSD<br />
file for cyclic data transmission. The master selects one of the possibilities to<br />
configure the inverter and then start the bus. These possibilities are called<br />
parameter process data object (PPO types) and always contain the process data<br />
channel (PZD) and sometimes also a parameter channel (PKW0). The Devices<br />
of the 5 th generation of STÖBER inverters provide five different PPO types to<br />
choose from for the establishment of this user data structure.<br />
To be able to use the functionality of process data transmission, the applicable<br />
blocks must be activated by the PC software POSITool. This is done by selecting<br />
a suitable application in user-prompted commissioning and then downloading it to<br />
the inverter. PPO types 3 and 4 do not need a separate memory area for the<br />
PKW1 service of the DP-V1 protocol.<br />
PKW<br />
PZD<br />
PKE IND<br />
PWE<br />
PZD1, 2, 3, 4, 5 6<br />
Bytes 0 1… … 19<br />
PPO1<br />
PPO2<br />
PPO3<br />
PPO4<br />
PPO5<br />
PKW : Parameter ID value<br />
PZD : Process data<br />
PKE : Parameter ID<br />
IND : Subindex in byte 2, Byte 3 is reserved<br />
PWE : Parameter value<br />
Fig. 8-1: PPO-Typen<br />
WE KEEP THINGS MOVING<br />
ID 441687.03<br />