Parameter Overview<br />

Operation manual<br />

11<br />

A95 PZD ActValue Mapping:<br />

The source parameters are entered in A94/A95 which contain the actual values/<br />

status bits of the inverter which are sent to the PLC via PROFIBUS.<br />

Example: When entered in A94.0 = E200, this means that the first byte (length<br />

of E200) which is transferred by the bus contains the contents of parameter<br />

E200. The subsequent data are transferred via the bus in the same way. It is<br />

absolutely necessary that the length of the entered parameters be known.<br />

Axes: Global<br />

Data type: 7<br />

Value: see above<br />

PNU:<br />

205F hex<br />

Subindex: 6<br />

A97 PZD ActValue Len:<br />

Indicator parameter which indicates the length in bytes of the current process<br />

data with actual values (data from inverter to PROFIBUS master) for the current<br />

parameterization.<br />

Axes: Global<br />

Data type: 5<br />

Value: see above<br />

PNU:<br />

2061 hex<br />

Subindex: 1<br />

A100 Fieldbus scaling:<br />

The selection is made here bet<strong>we</strong>en internal raw values and whole numbers for<br />

the representation/scaling of process data values during transmission via PZD<br />

channel. Regardless of this setting, the representation is always the whole<br />

number via PKW channel and the non cyclic parameter channel.<br />

CAUTION<br />

When "0:integer" is parameterized (scaled values), the runtime load increases<br />

significantly and it may become necessary to increase A150 cycle time to avoid<br />

the fault "57:runtime usage" or "35:Watchdog".<br />

With few exceptions, the PKW channel is always transferred in scaled format.<br />

Axes: Global<br />

Data type: 5<br />

Value: 0:Standard<br />

1:raw value<br />

PNU:<br />

2064 hex<br />

Subindex: 1<br />