Parameter Overview<br />

Operation manual<br />

11<br />

A85 PROFIBUS diagnostic:<br />

Indication of internal inverter diagnostic information on the PROFIBUS DP<br />

interface.<br />

Axes: Global<br />

Dat entyp: 6<br />

Wert: Bitfeld mit 16 Bits<br />

PNU:<br />

2055 hex<br />

Subindex: 1<br />

A86 PROFIBUS configuration:<br />

The inverter offers various ways (PPO types) to transfer cyclic user data via<br />

PROFIBUS DP. These can be configured in the GSD file STOE5005.gsd on the<br />

controller (bus master). This indication parameter can be used to check which of<br />

the possible configurations was chosen.<br />

Axes: Global<br />

Data type: 5<br />

Value: chosen configuration<br />

PNU:<br />

2056 hex<br />

Subindex: 1<br />

A90 PZD Setpoint Mapping:<br />

The target parameters are entered in A90/A91 for the reference values/control<br />

bits which are sent by the PLC to the device via PROFIBUS.<br />

Example: When A90.0 = A180 is entered, this means that the first byte (length of<br />

A180) which is received by the bus is transferred to parameter A180.<br />

Subsequent data are transferred in the same way to the entered parameters. It<br />

is absolutely necessary that the length of the entered parameters be known.<br />

Axes: Global<br />

Data type: 7<br />

Value: see above<br />

PNU:<br />

205A hex<br />

Subindex: 6<br />

WE KEEP THINGS MOVING<br />

ID 441687.03<br />