Parameter Overview<br />
Operation manual<br />
11<br />
A85 PROFIBUS diagnostic:<br />
Indication of internal inverter diagnostic information on the PROFIBUS DP<br />
interface.<br />
Axes: Global<br />
Dat entyp: 6<br />
Wert: Bitfeld mit 16 Bits<br />
PNU:<br />
2055 hex<br />
Subindex: 1<br />
A86 PROFIBUS configuration:<br />
The inverter offers various ways (PPO types) to transfer cyclic user data via<br />
PROFIBUS DP. These can be configured in the GSD file STOE5005.gsd on the<br />
controller (bus master). This indication parameter can be used to check which of<br />
the possible configurations was chosen.<br />
Axes: Global<br />
Data type: 5<br />
Value: chosen configuration<br />
PNU:<br />
2056 hex<br />
Subindex: 1<br />
A90 PZD Setpoint Mapping:<br />
The target parameters are entered in A90/A91 for the reference values/control<br />
bits which are sent by the PLC to the device via PROFIBUS.<br />
Example: When A90.0 = A180 is entered, this means that the first byte (length of<br />
A180) which is received by the bus is transferred to parameter A180.<br />
Subsequent data are transferred in the same way to the entered parameters. It<br />
is absolutely necessary that the length of the entered parameters be known.<br />
Axes: Global<br />
Data type: 7<br />
Value: see above<br />
PNU:<br />
205A hex<br />
Subindex: 6<br />