<strong>ZonePRO</strong> TM<br />
Zone Controllers<br />
Section 4<br />
VOLUME<br />
ZC-6 – The ZC-6 is a push-button up/down input or output volume controller.<br />
ZC-6<br />
A<br />
B<br />
C<br />
D<br />
ZC-7 – The ZC-7 is a programmable zone controller that allows control of page steering via<br />
four momentary push buttons. The ZC-7 has 5 states: button A pressed, button B pressed,<br />
button C pressed, button D pressed, and “no button pressed” being the 5th state.<br />
ZC-7<br />
VOLUME<br />
SELECT<br />
A<br />
B A<br />
C<br />
B<br />
D<br />
C<br />
D<br />
ZC-8 – The ZC-8 is used for combination up/down output volume control and four position<br />
source selection control.<br />
ZC-8<br />
C D E F<br />
B<br />
G<br />
A<br />
H<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
ZC-9 – The ZC-9 provides source selection control via an eight position rotary selector.<br />
G<br />
H<br />
ZC-9<br />
INPUTS<br />
RELAY/<br />
CONTROL<br />
SWITCH VOLTAGE<br />
CLOSURE 5-24 VDC<br />
RJ45 - CONNECT ONLY TO<br />
ZONE CONTROLLER INPUT<br />
OUT<br />
IN<br />
ZC-FIRE – The ZC-FIRE is the interface to generic fire alarm relays. When the fire alarm<br />
activates, the general purpose relay can typically be programmed to close if normally<br />
open or vices-versa. The ZC-FIRE interface unit monitors the state of the relay (n.o. or<br />
n.c.) and upon the state of change, notifies the <strong>ZonePRO</strong> to mute the outputs or load a<br />
pre-programmed “Fire” scene. Control Voltage (5-24 VDC) can also be used for triggering the<br />
ZC-FIRE.<br />
The ZC-FIRE must be assigned as ID#2 and connected to the <strong>ZonePRO</strong>’s top ZC<br />
Input connector for fire control.<br />
13