SDI<br />

Specifications<br />

<strong>and</strong> Commentary<br />

Recommended Maximum Spans for Construction <strong>and</strong><br />

Maintenance Loads St<strong>and</strong>ard for 1 1 /2 Inch <strong>and</strong> 3 Inch <strong>Ro<strong>of</strong></strong><br />

Max. Recommended Spans<br />

Span Span <strong>Ro<strong>of</strong></strong> <strong>Deck</strong> Cantilever<br />

Type Condition Ft.-In. Meters Ft.-In. Meters<br />

Narrow NR22 1 3'-10" 1.15 m<br />

Rib <strong>Deck</strong> NR22 2 or more 4'-9" 1.45 m<br />

NR20 1 4'-10" 1.45 m<br />

NR20 2 or more 5'-11" 1.80 m<br />

NR18 1 5'-11" 1.80 m<br />

NR18 2 or more 6'-11" 2.10m<br />

Intermediate IR22 1 4'-6" 1.35 m<br />

Rib <strong>Deck</strong> IR22 2 or more 5'-6" 1.65 m<br />

lR20 1 5'-3" 1.60 m<br />

IR20 2 or more 6'-3" 1.90 m<br />

Wide Rib WR22 1 5'-6" 1.65 m<br />

<strong>Deck</strong> WR22 2 or more 6'-6" 1.75 m<br />

WR20 1 6'-3" 1.90 m<br />

WR20 2 or more 7'-5" 2.25 m<br />

WR18 1 7'-6" 2.30 m<br />

WR18 2 or more 8'-10" 2.70m<br />

Deep Rib 3DR22 1 11'-0" 3.35 m<br />

<strong>Deck</strong> 3DR22 2 or more 13'-0" 3.95 m<br />

3DR20 1 12'-6" 3.80 m<br />

3DR20 2 or more 14'-8" 4.45 m<br />

3DR18 1 15'-0" 4.55 m<br />

3DR18 2 or more 17'-8" 5.40 m<br />

Construction <strong>and</strong> maintenance loads:<br />

SPANS are governed by a maximum<br />

stress <strong>of</strong> 26 ksi (180 MPa) <strong>and</strong> a maximum<br />

deflection <strong>of</strong> L/240 with a<br />

200 pound (0.89 kN) concentrated<br />

load at midspan on a I'-0" (300 mm)<br />

wide section <strong>of</strong> deck. If the designer<br />

contemplates loads <strong>of</strong> greater magnitude,<br />

spans shall be decreased or the<br />

thickness <strong>of</strong> the steel deck increased<br />

as required.<br />

All loads shall be distributed by<br />

appropriate means to prevent damage<br />

to the completed assembly during<br />

construction.<br />

1'-0"<br />

1'-2"<br />

1'-7"<br />

.30 m<br />

.35 m<br />

.45 m<br />

1'-2" .35m<br />

1'-5" .40m<br />

1'-11"<br />

2'-4"<br />

.55 m<br />

.70 m<br />

2'-10" .85m<br />

3'-5"<br />

3'-11"<br />

4'-9<br />

1.05 m<br />

1.20 m<br />

1.45 m<br />

Cantilever loads:<br />

Construction phase load <strong>of</strong> 10 psf<br />

(0.48 kPa) on adjacent span <strong>and</strong> cantilever,<br />

plus 200 pound load (0.89 kN)<br />

at end <strong>of</strong> cantilever with a stress limit<br />

<strong>of</strong> 26 ksi (180 MPa).<br />

Service load <strong>of</strong> 45 psf (2.15 kPa)<br />

on adjacent span <strong>and</strong> cantilever, plus<br />

100 pound load (0.44 kN) at end <strong>of</strong><br />

cantilever with a stress limit <strong>of</strong> 20 ksi<br />

(140 MPa).<br />

Deflection limited to L/240 <strong>of</strong> adjacent<br />

span for interior span <strong>and</strong> deflection<br />

at end <strong>of</strong> cantilever to L/240 <strong>of</strong><br />

overhang.<br />

Notes:<br />

1. Adjacent span: Limited to those<br />

spans shown in Section 3.4 <strong>of</strong> <strong>Ro<strong>of</strong></strong><br />

<strong>Deck</strong> Specifications. In those<br />

instances where the adjacent span is<br />

less than 3 times the cantilever span,<br />

the individual manufacturer should<br />

be consulted for the appropriate<br />

cantilever span.<br />

2. Sidelaps must be attached at end<br />

<strong>of</strong> cantilever <strong>and</strong> at a maximum <strong>of</strong> 12<br />

inches (300 mm) on center from end.<br />

3. No permanent suspended loads are<br />

to be supported by the steel deck.<br />

4. The deck must be completely<br />

attached to the supports <strong>and</strong> at the<br />

sidelaps before any load is applied to<br />

the cantilever.<br />

4. Installation & Site Storage<br />

4.1 Site Storage: <strong>Steel</strong> deck shall<br />

be stored <strong>of</strong>f the ground with one<br />

end elevated to provide drainage,<br />

<strong>and</strong> shall be protected from the<br />

elements with a waterpro<strong>of</strong><br />

covering, ventilated to avoid<br />

condensation.<br />

11