FLOOR-CEILING ASSEMBLIES WITH COMPOSITE DECK <strong>Vulcraft</strong> <strong>Deck</strong>s have been tested by Underwriters Laboratories Inc. for their Fire Resistance Ratings. In as much as new listings are continually being added, please contact the factory if your required design is not listed below. The cellular decks listed comply with U.L. 209 for use as Electrical Raceways. Restrained Assembly Rating 3/4 Hr. 1 Hr. 1 1 /2 Hr. 2 Hr. 60 Type <strong>of</strong> Protection Unprotected <strong>Deck</strong> Exposed Grid Cementitious Sprayed Fiber Unprotected <strong>Deck</strong> Gypsum Board Cementitious Sprayed Fiber Unprotected <strong>Deck</strong> Exposed Grid Gypsum Board Cementitious Concrete Thickness & Type (1) 2 1 /2" LW 2 1 /2" NW 2" NW&LW 2 1 /2" NW&LW 2" NW&LW 2 1 /2" NW&LW 2 1 /2" LW 3 1 /2" NW 2 1 /2" NW 2" NW&LW 2 1 /2" NW&LW 2" NW&LW 2 1 /2" NW&LW 3" LW 4" NW 2 1 /2" NW 2 1 /2" NW 2" NW&LW 2 1 /2" LW 2 1 /2" NW&LW 2 1 /2" NW U.L. Design No. (2,3,4) Classified <strong>Deck</strong> Type Unrestrained Beam Rating Fluted <strong>Deck</strong> Cellular <strong>Deck</strong> (5) D914 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1 Hr. D916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D216 + 1.5VL,1.5VLI,2VLI,3VLI 2VLP, 3VLP 2,3 Hr. D743 # 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. D703 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1.5 Hr. D712 * 3VLI 3VLP 2 Hr. D722 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. D739 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3,4 Hr. D759 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D859 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. D832 * 1.5VLI,2VLI,3VLI 3VLP 1,1.5,2,3 Hr. D847 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,3 Hr. D858 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,4 Hr. D871 * 2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D914 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1 Hr. D916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D502 * 1.5VL,1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5,2 Hr. D743 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. D703 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1.5 Hr. D712 * 3VLI 3VLP 2 Hr. D722 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. D739 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3,4 Hr. D759 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D859 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. D832 * 1.5VLI,2VLI,3VLI 3VLP 1,1.5,2,3 Hr. D847 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,3 Hr. D858 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,4 Hr. D871 * 2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. D216 + 1.5VL,1.5VLI,2VLI,3VLI 2VLP, 3VLP 2,3 Hr. D502 + 1.5VL,1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5,2 Hr. D743 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. D746 * 1.5VLI 1,1.5,2,3 Hr. D752 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2, Hr. D703 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1.5 Hr. D712 * 3VLI 3VLP 2 Hr. D716 * 1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5,2 Hr. D722 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. D739 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3,4 Hr. D745 * 2VLI,3VLI 1,1.5,2, Hr. D750 * 1.5VLI,2VLI,3VLI 1.5,2 Hr. D755 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D759 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. D760 * 2VLI,3VLI 1,1.5,2,3,4 Hr. D730 * 2VLI,3VLI 2VLP, 3VLP 1.5,2 Hr. D742 * 1.5VLI,2VLI,3VLI 1,1.5 Hr.
Restrained Assembly Rating 2 Hr. (continued) 3 Hr. 4 Hr. Type <strong>of</strong> Protection Sprayed Fiber Unprotected <strong>Deck</strong> Exposed Grid Cementitious Sprayed Fiber Unprotected <strong>Deck</strong> Cementitious Sprayed Fiber Concrete Thickness & Type (1) 2" NW&LW 2 1 /2" NW&LW 2 1 /2" LW 2 1 /2" NW 3 1 /4" LW 3 1 /4" LW 4 1 /2" NW 3 1 /4" NW 2" NW&LW 2 1 /2" LW 2 1 /2" NW&LW 3 1 /4" LW 3 1 /4" NW 2" NW&LW 2 1 /2" NW&LW 2 1 /2" NW 3 1 /4" LW 4 3 /16" LW 5 1 /4" NW 2 1 /2" NW&LW 3 1 /4" LW 2 1 /2" NW&LW 3 1 /4" LW U.L. Design No. (2,3,4) Classified <strong>Deck</strong> Type Unrestrained Beam Rating Fluted <strong>Deck</strong> Cellular <strong>Deck</strong> (5) 859 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. 822 * 2VLI,3VLI 2VLP, 3VLP 1 Hr. 825 * 1.5VLI,2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. 831 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. 832 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 833 * 1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5 Hr. 847 * 2VLI,3VLI 3VLP 1,1.5,3 Hr. 858 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,4 Hr. 861 * 12VLI,3VLI 1,1.5 Hr. 870 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,2 Hr. 871 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. 862 * 2VLI,3VLI 1 Hr. 864 * 3VLI 3VLP 1.5 Hr. 860 * 2VLI,3VLI 1,1.5,2 Hr. 733 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5Hr. 826 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2 Hr. 840 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 907 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,2 Hr. 913 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1 Hr. 916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 920 # 2VLI,3VLI 2VLP, 3VLP 1.5 Hr. 902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 216 + 1.5VL,1.5VLI,2VLI,3VLI 2VLP, 3VLP 2,3 Hr. 743 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. 746 * 1.5VLI 1,1.5,2,3 Hr. 703 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1.5 Hr. 708 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1.5,3 Hr. 739 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3,4 Hr. 755 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 759 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 760 * 2VLI,3VLI 1,1.5,2,3,4 Hr. 754 * 1.5VLI,2VLI,3VLI 1.5,2 Hr. 742 * 1.5VLI,2VLI,3VLI 1,1.5 Hr. 859 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. 816 * 1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5,2 Hr. 831 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2 Hr. 832 * 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 833 * 1.5VLI,2VLI,3VLI 2VLP, 3VLP 1.5 Hr. 858 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,4 Hr. 871 * 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,3 Hr. 864 3VLI 3VLP 1.5 Hr. 860 * 2VLI,3VLI 1,1.5,2 Hr. 902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 902 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 916 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3 Hr. 918 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 919 # 1.5VL,1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5 Hr. 760 2VLI,3VLI 1,1.5,2,3,4 Hr. 739 1.5VLI,2VLI,3VLI 1.5VLP, 2VLP, 3VLP 1,1.5,2,3,4 Hr. 754 1.5VLI,2VLI,3VLI 1.5,2 Hr. 858 2VLI,3VLI 2VLP, 3VLP 1,1.5,2,4 Hr. 860 2VLI,3VLI 1,1.5,2 Hr. NOTES: 1. Concrete thickness is thicness <strong>of</strong> slab above deck, in. 2. Refer to the U.L. "Fire Resistance Directory" for the necessary construction details. 3. Cellular deck finish shall be galvanized. 4. Fluted deck finish shall be galvanized unless noted otherwise. + Denotes fluted deck finish is not critical when used in D2-- & D5-- Series designs. <strong>Deck</strong> finish shall be galvanized or phosphatized/painted. * Fluted deck finish is critical for fire resitance. Fluted deck finish shall be galvanized or phospatized/painted. This paint is a special type <strong>of</strong> paint <strong>and</strong> is compatible with the spray-applied fire protection <strong>and</strong> is U.L. approved for use in the denoted D7-- & D8 Series designs. # Denotes fluted deck finish is not critical for fire resistance. Fluted deck finish shall be galvanized/painted. 5. <strong>Vulcraft</strong> cellular deck units are approved by U.L. for use as electrical raceways under U.L St<strong>and</strong>ard 209. 61
- Page 2 and 3:
VULCRAFT A Division of Nucor Corpor
- Page 4 and 5:
TECHNICAL PRODUCT INFORMATION Appro
- Page 6 and 7:
1.5 F Maximum Sheet Length 42'-0 Ex
- Page 8 and 9:
3 N, NI, NA, NIA Maximum Sheet Leng
- Page 10 and 11:
CELLULAR DECK Galvanized Only For:
- Page 12 and 13: SDI Specifications and Commentary R
- Page 14 and 15: SDI Specifications and Commentary W
- Page 16 and 17: SDI Short Form Specifications FOR S
- Page 18 and 19: SDI Short Form Specifications FOR S
- Page 20 and 21: ACCESSORIES VALLEY DETAIL DETAIL WH
- Page 22 and 23: 0.6 C, CSV CONFORM MAXIMUM CONSTRUC
- Page 24 and 25: 1.0 C, CSV CONFORM MAXIMUM CONSTRUC
- Page 26 and 27: 1.3 C, CONFORM MAXIMUM CONSTRUCTION
- Page 28 and 29: 1.5 C CONFORM MAXIMUM CONSTRUCTION
- Page 30 and 31: 2 C CONFORM MAXIMUM CONSTRUCTION CL
- Page 32 and 33: 3 C CONFORM MAXIMUM CONSTRUCTION CL
- Page 34 and 35: SDI Specifications and Commentary F
- Page 36 and 37: SDI Specifications and Commentary F
- Page 38 and 39: SDI Specifications and Commentary F
- Page 40 and 41: SDI Short Form Specifications FOR N
- Page 42 and 43: FLOOR-CEILING ASSEMBLIES WITH FORM
- Page 44 and 45: 1.5 VL, VLI Maximum Sheet Length 42
- Page 46 and 47: 1.5 VLR Maximum Sheet Length 42'-0
- Page 48 and 49: 2 VLI Maximum Sheet Length 42'-0 Ex
- Page 50 and 51: 3 VLI Maximum Sheet Length 42'-0 Ex
- Page 52 and 53: SDI Specifications and Commentary F
- Page 54 and 55: SDI Specifications and Commentary l
- Page 56 and 57: SDI Specifications and Commentary 5
- Page 58 and 59: SDI Specifications and Commentary F
- Page 60 and 61: SDI Short Form Specifications FOR C
- Page 64 and 65: Es=29500KSI W=W+Wc, PSF Deck t W 22
- Page 66 and 67: SDI POUR STOP SELECTION TABLE SLAB
- Page 68 and 69: SDI Code of Recommended Standard Pr
- Page 70 and 71: TYPICAL FASTENER LAYOUT DIAPHRAGM S
- Page 72 and 73: 1.5 (B, BI, F, A) 22 ALLOWABLE DIAP
- Page 74 and 75: 1.5 (B, F, A) 22 ALLOWABLE DIAPHRAG
- Page 76 and 77: 1.5 (B, BI, F, A) 20 ALLOWABLE DIAP
- Page 78 and 79: 1.5 (B, F, A) 20 ALLOWABLE DIAPHRAG
- Page 80 and 81: 1.5 (B, BI, F, A) 18 ALLOWABLE DIAP
- Page 82 and 83: 1.5 (B, F, A) 18 ALLOWABLE DIAPHRAG
- Page 84 and 85: 3 (N, NI) ALLOWABLE DIAPHRAGM SHEAR
- Page 86 and 87: 3N ALLOWABLE DIAPHRAGM SHEAR STRENG
- Page 88 and 89: 0.6C, 1.0C, & 1.3C DECK WITH LIGHTW
- Page 90 and 91: 0.6C & 1.0C DECK WITH TYPE I INSULA
- Page 92 and 93: 0.6C & 1.0C DECK WITH TYPE II INSUL
- Page 94 and 95: 1.5, 2, & 3 COMPOSITE DECK WITH LIG
- Page 96 and 97: 94 NOTES
- Page 98 and 99: PUBLICATIONS & SOFTWARE VULCRAFT -