08.10.2014 Views

Vulcraft Steel Roof and Floor Deck Catalog - University of Maryland ...

Vulcraft Steel Roof and Floor Deck Catalog - University of Maryland ...

Vulcraft Steel Roof and Floor Deck Catalog - University of Maryland ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VULCRAFT, a leader in the steel joist <strong>and</strong><br />

joist girder industry <strong>of</strong>fers a complete range <strong>of</strong><br />

steel decking at the five strategically located<br />

deck manufacturing facilities. The deck is<br />

accurately roll formed in varying configurations<br />

on the most modern high-speed roll forming<br />

equipment available.<br />

<strong>Steel</strong> ro<strong>of</strong> <strong>and</strong> floor decks have long been<br />

recognized for their economy because <strong>of</strong> their<br />

light weight <strong>and</strong> high strength-to-weight ratio.<br />

They provide a durable <strong>and</strong> attractive ro<strong>of</strong> or<br />

floor system for fast all-weather construction.<br />

<strong>Steel</strong> decks also provide excellent lateral<br />

diaphragm action thus reducing the necessity<br />

for structural bracing <strong>and</strong> their incombustible<br />

nature assures architects, engineers <strong>and</strong><br />

owners <strong>of</strong> excellent fire ratings.<br />

FINISHES:<br />

<strong>Vulcraft</strong> <strong>of</strong>fers a selection <strong>of</strong> three finishes:<br />

prime painted, galvanized <strong>and</strong> black<br />

(uncoated).<br />

Prime painted - prior to applying a baked-on<br />

acrylic medium gray primer, the cold rolled<br />

sheet is chemically cleaned <strong>and</strong> pre-treated.<br />

An <strong>of</strong>f-white primer is available at an additional<br />

cost.<br />

Galvanized - <strong>Vulcraft</strong> galvanized decks are<br />

supplied from mill coated sheets conforming to<br />

ASTM-A653-94, Structural Quality, <strong>and</strong> Federal<br />

Spec. QQ-S-775, <strong>and</strong> they are <strong>of</strong>fered in two<br />

zinc coated finishes.<br />

(1) G-90 - .9 ounce/sq.ft.<br />

(2) G-60 - .6 ounce/sq.ft.<br />

V U L C R A F T , a division <strong>of</strong> Nucor<br />

Corporation, has provided this catalog for use<br />

by engineers <strong>and</strong> architects, using <strong>Vulcraft</strong> steel<br />

decks. It includes all products available at the<br />

time <strong>of</strong> printing. We reserve the right to<br />

change, revise or withdraw any products or<br />

procedures without notice.<br />

The information presented in this catalog<br />

has been prepared in accordance with<br />

recognized engineering principles <strong>and</strong> is for<br />

general information only. While it is believed to<br />

be accurate, this information should not be<br />

used or relied upon for any specific application<br />

without competent pr<strong>of</strong>essional examination<br />

<strong>and</strong> verification <strong>of</strong> its accuracy, suitability <strong>and</strong><br />

applicability by an engineer, architect or other<br />

licensed pr<strong>of</strong>essional.<br />

TABLE OF CONTENTS<br />

Typical Dimensions .........................................................2<br />

ROOF DECK (TYPE “B”, “F”, “A”, “N”, AND “E”)<br />

1.5B.................................................................................3<br />

1.5F .................................................................................4<br />

1.5A.................................................................................5<br />

3N ..................................................................................6<br />

1.0E.................................................................................7<br />

Cellular <strong>Deck</strong>...................................................................8<br />

Specifications <strong>and</strong> Commentaries.......................9 thru 16<br />

Fire Resistance Ratings ................................................17<br />

Accessories...................................................................18<br />

NON-COMPOSITE FLOOR DECK TYPE (TYPE “C”) (CONFORM)<br />

Conform (Type C)..........................................................19<br />

0.6C.........................................................................20, 21<br />

1.0C.........................................................................22, 23<br />

1.3C.........................................................................24, 25<br />

1.5C.........................................................................26, 27<br />

2C ..........................................................................28, 29<br />

3C ..........................................................................30, 31<br />

Specifications <strong>and</strong> Commentaries.....................32 thru 39<br />

<strong>Floor</strong>-Ceiling Assemblies with Form <strong>Deck</strong>s...................40<br />

Non-Composite & Composite <strong>Deck</strong> Details...................41<br />

COMPOSITE FLOOR DECK (TYPE “VL”)<br />

1.5 VL & 1.5 VLI ......................................................42, 43<br />

1.5 VLR....................................................................44, 45<br />

2 VLI........................................................................46, 47<br />

3 VLI........................................................................48, 49<br />

Specifications <strong>and</strong> Commentaries.....................50 thru 59<br />

<strong>Floor</strong>-Ceiling Assemblies with Composite <strong>Deck</strong>......60, 61<br />

Maximum Cantilever Spans...........................................62<br />

Web Crippling Data .......................................................63<br />

SDI Pour Stop Selection Table......................................64<br />

CODE OF RECOMMENDED STANDARD PRACTICE<br />

Code <strong>of</strong> Recommended St<strong>and</strong>ard Practice.............65, 66<br />

DIAPHRAGM SHEAR STRENGTH AND STIFFNESS<br />

Diaphragm Shear Strength <strong>and</strong> Stiffness......................67<br />

Typical Fastener Layout/ Example................................68<br />

1.5 B, F, A .........................................................69 thru 80<br />

3N ....................................................................81 thru 84<br />

Conform (Type “C”) Normal Wt. Concrete.....................85<br />

Conform (Type “C”) Light Wt. Concrete.........................86<br />

Conform (Type “C”) Type 1 Fill................................87, 88<br />

Conform (Type “C”) Type 2 Fill................................89, 90<br />

Composite <strong>Deck</strong>......................................................91, 92<br />

Publications...................................................................96<br />

FRONT COVER PICTURE:<br />

The <strong>University</strong> <strong>of</strong> Houston’s indoor practice facility can be<br />

configured for football, track, tennis, basketball <strong>and</strong> volleyball.<br />

Development Manager: Hines Interests; Design Architect: HOK Sports Facilities<br />

Group; Production Architect: Kendall/Heaton Associates; General Contractor: D.E.<br />

Harvey Builders; <strong>Steel</strong> Fabricator: Eagle Fab; <strong>Steel</strong> Erector: Postel-Smith, Inc.<br />

2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!