06.11.2014 Views

PRIMERGY RX300 S3

PRIMERGY RX300 S3

PRIMERGY RX300 S3

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong><br />

System configurator and order-information guide<br />

May 2006<br />

Contents<br />

Instructions<br />

Configuration<br />

diagram<br />

Configurator<br />

0 System software<br />

I Basic unit<br />

I I Processor<br />

I I I Memory<br />

I V Graphics<br />

V Accessible drives<br />

VI Hard disk drives<br />

VII SCSI controller<br />

V I I I<br />

Communication/Network<br />

I X System Management Products (RemoteView)<br />

X<br />

Miscellaneous<br />

X I Country specific power cord<br />

Change<br />

report<br />

<strong>PRIMERGY</strong> Server


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Instructions<br />

This document contains basic product and configuration information that will enable you to configure your system via<br />

P C - / S y s t e m - A r c h i t e c t .<br />

Only these tools will ensure a fast and proper configuration of your <strong>PRIMERGY</strong> server or your complete<br />

P R I M E R G Y R a c k s y s t e m .<br />

You can configure your individual <strong>PRIMERGY</strong> server in order to adjust your specific requirements.<br />

The System configurator is divided into several chapters that are identical to the current price list and PC-/SystemArchitect.<br />

Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through<br />

the configurator by following the lines from the top to the bottom.<br />

Section III Memory, example<br />

There are X memory slots which can be equipped with XXX MB.<br />

It is permissible to make up to X passes through the memory upgrade options<br />

X<br />

times<br />

S26361-XXX-XXX<br />

S26361-XXX-XXX<br />

Memory XXX MB Memory XXX MB<br />

max. X times per system max. X times per system<br />

In one chapter you can only select as many components (here 4x) as the arrow indicates. 4x<br />

Please note that there are information symbols which indicate necessary information.<br />

Further information in the internet see:<br />

http://www.primergy.com<br />

http://extranet.fujitsu-siemens.com/primergy<br />

(internet)<br />

(extranet)<br />

Prices and availability see price list and PC-/System-Architect<br />

Subject to change and errors excepted<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 2 of 21


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Configuration diagram <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong><br />

System unit ( I )<br />

board front side<br />

middle<br />

Channel 0 (2 Modules) Bay for LocalView LCD<br />

Xeon DP or 3.5"x 0,5" Floppy disk<br />

Channel I (2 Modules)<br />

Channel II (2 Modules) Air channel<br />

Xeon<br />

DP<br />

Channel III (2 Modules)<br />

Bay for 5,25"x 0,5" IDE-CD<br />

or DVD-ROM<br />

Memory ( III ) Processor ( II )<br />

Accessible drives ( V )<br />

rear<br />

side<br />

Fan 1 - Fan 4<br />

1 . P S U 2 . P S U Needs space for 2<br />

hard disk drives!<br />

Fan 5 - Fan 8 3.5"x1,6"<br />

Redundant system-<br />

Redundant power fans option Backup drive option<br />

supply option<br />

Hard disk drives ( VI )<br />

RAID 5 support Licence key + 256MB Cache left side<br />

onboard<br />

Licence key + 256MB Cache+BBU<br />

Extension slots for 3.5"x1" SAS or SATA<br />

SCSI Controller ( VII )<br />

Disk Array ( VIII )<br />

Communication/Network ( IX ) 3.5"x1" SAS or SATA<br />

Miscellaneous ( X )<br />

RISER option<br />

Slot 5: PCIe x8, Low Profile 3.5"x1" SAS or SATA<br />

Slot 6: Slot 7: Slot 8:<br />

HOT PLUG<br />

Slot 4: PCIe x4, Low Profile (mech. x8)<br />

PCI-X 64 PCI-X 64 PCI-X 64<br />

HOT PLUG<br />

Slot 3: PCIe x4, Low Profile (mech. x8) 3.5"x1" SAS or SATA<br />

133 MHz 133 MHz 133 MHz<br />

Slot 2: PCI-X 64-Bit / 133MHz, Low Profile 3.5"x1" SAS or SATA<br />

Standard Standard Standard<br />

Slot 1: PCI-X 64-Bit / 133MHz, Low Profile 3.5"x1" SAS or SATA<br />

short short long<br />

All l o w p r o f i l e s l o t s a r e c o v e r e d , i f P C I - r i s e r c a r d c o n f i g u r e d<br />

right<br />

side<br />

Key:<br />

Included in basic unit<br />

Option<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 3 of 21


System configurator and order-information guide<br />

Start "<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong>" <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

SW - Configurator 32 bit<br />

with OEM-Software<br />

without OEM-Software<br />

for <strong>PRIMERGY</strong> Server for <strong>PRIMERGY</strong> Server<br />

as soon as available Later use of OEM operating system<br />

VMware-Software software is not allowed,<br />

- VCMS VirtualCenter Management Server apart from few VMware<br />

- ESX Server and ESX Virtual Infrastructure Node Usage of OEM SW from MS is add-ons<br />

- P2V Assistant Enterprise Edition not possible under ESX<br />

For all SW products please refer to the corresponding software configurator accessible via<br />

the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.<br />

Microsoft - Software: W **) Novell - Software: ***) PRIMECLUSTER *)<br />

- Windows Server 2003, - N e t W a r e - Clustering<br />

Web Edition (nur Englisch) - NetWare Cluster NCS - Load Balancing<br />

Standard Edition certificate<br />

Enterprise Edition - Open Enterprise Server<br />

contains<br />

NetWare<br />

SCO - Software: **)<br />

CITRIX-Software for - UnixWare<br />

Windows: W-MF<br />

- Multiuser SW MetaFrame Linux - Software: **)<br />

LoadBalancing - SuSE Linux Enterprise Server<br />

Additional User Licences - SuSE Professional Linux<br />

- Red Hat Enterprise Linux<br />

MultiPath, Duplex Data Manager (DDM)<br />

W2K; W2K3 Linux (W-DDM)<br />

DataMigrationManager W2K, W2K3<br />

Details eg. version numbers are published<br />

in the separate SW-Configurator<br />

Manageability Software: V**) *) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under<br />

- Altiris Server Deployment http://extranet.fujitsu-siemens.com/primecluster<br />

- vPMS 2006std<br />

**) Pay attention to release and order information in PRINCE -> Operating System<br />

http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm<br />

***) Supply over distribution or procurement from FSC VP BC Software<br />

You'll find single software configurators and release lists (OS-matrix/system management/security) under following addresses:<br />

for internal users:<br />

for partners:<br />

http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm<br />

http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm<br />

Continue with <strong>PRIMERGY</strong><br />

HW configurator<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 4 of 21


System configurator and order-information guide<br />

Start "<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong>" <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

SW Configurator EM64T<br />

with OEM-Software<br />

without OEM-Software<br />

for <strong>PRIMERGY</strong> Server for <strong>PRIMERGY</strong> Server<br />

Later use of OEM operating system<br />

For all SW products please refer to the corresponding software is not allowed.<br />

software configurator accessible via the Extranet under<br />

"Configuration & Tools, -All configurations, -Software,<br />

URL see below.<br />

as soon as available<br />

Microsoft - Software: W Linux - Software: L *) **)<br />

only - Windows Server 2003, only - SuSE Linux Enterprise Server<br />

EM64T x64 Standard Edition EM64T - Red Hat Enterprise Linux<br />

x64 Enterprise Edition<br />

CITRIX-Software for<br />

only Windows: W-MF<br />

EM64T - Presentation Server<br />

LoadBalancing<br />

Additional User Licences<br />

only MultiPath, Duplex Data Manager (DDM) only VMware GSX Server<br />

EM64T Windows, Linux (W-DDM)<br />

EM64T and GSX Virtual Infrastructure Node<br />

Details eg. version numbers are published<br />

in the separate SW-Configurator<br />

*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under<br />

http://extranet.fujitsu-siemens.com/primecluster<br />

**) Pay attention to release and order information in PRINCE -> Operating System<br />

http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm<br />

You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:<br />

for internal users:<br />

for partners:<br />

http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm<br />

http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm<br />

Continue with <strong>PRIMERGY</strong><br />

HW configurator<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 5 of 21


System configurator and order-information guide<br />

Start <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section I Basic unit<br />

System unit consisting of:<br />

* 2U Housing including one power supply module<br />

- hot plug Power supply unit with 1 PSU module and power cord rack 4m lenght<br />

(can be upgraded with one additional PSU module)<br />

* Fan unit with 4 hot plug system-fans and control logic for 8 fans<br />

- Additional 4 hot plug system-fans as a redundant fans option (option)<br />

* SAS Backplane for 6x 3.5" HD with cable-less connection to motherboard<br />

* The basic units are offered with 1GB, 2GB or 4GB Memory as default.<br />

* Drives/Bays<br />

- 6 bays 1" for hot plug 3.5" HD (1" high)<br />

- 1 bay for 3.5" and 1.6" high Backup device, consumes 2 bays 1" for hot plug HD<br />

- 1 bay IDE-CD- or DVD-ROM 0,5" height (option)<br />

- 1 bay for opt. LocalView LC-Display or floppy disk 1.44MB, 0,5" height<br />

* Integrated ServerView Diagnostics Technology for indication of internal failed components<br />

Mounting kit for <strong>RX300</strong> <strong>S3</strong> is part of the basic unit<br />

- 1 pair of telescopic rails<br />

- 1 Vario carrier DC-PC-3rd party Rack<br />

allows toolless adjustable in depth and easy mounting<br />

Mounting kit for mounting of servers in FSC 19" PRIMECENTER- racks<br />

and all server racks conforming to EIA standard EIA-310-D for 19" racks.<br />

Therefore the mounting kit is variable in depth from 704-900mm<br />

Systemboard with:<br />

* One CPU including a passive heat sink according to the configurator<br />

Xeon Dual Core CPU supporting 64Bit EM64T and Intel® VT / HT / DBS Technology.<br />

- ( VT =Virtualisation Technology, HT = Hyper Threading, DBS = Demand Based Switching )<br />

* Chipset Intel® 5000P (codenamed Blackford)<br />

* 5 PCI slots: 1x PCIe x8 low profile<br />

2x PCIe x4 low profile ( mechanical x8 ), hot plug PCI<br />

2x PCI-X 64Bit/133MHz low profile (3.3V)<br />

- 3 PCI Slots (Standard full height PCI System - with PCI Subchassis (risercard option))<br />

1x PCI-X 64Bit/133MHz long full height<br />

2x PCI-X 64Bit/133MHz short full height<br />

* 8 memory slots for max. 32GB RAM ( Fully Buffered DIMM = FBD533 / PC2-4200F ) available<br />

- Memory is divided into two branches, driven by a memory controller each.<br />

- Each branch has 2 channels with 2 DIMM slots each (bank 1 and bank 2)<br />

- Max. 4GB modules per slot are possible<br />

- Memory upgrade is possible per branch with modul pairs ( one pair / branch )<br />

- Memory mirrroring is supported branch to branch for 2 identical module pairs each in the same<br />

same memory bank of branch 0 and branch 1<br />

- Max. memory bandwidth and 4-way interleaving is supported with 2 identical memory pairs<br />

in one memory bank (one pair per branch) if mirroring is disabled<br />

- Chipkill is supported for memory modules,<br />

* One Fast-IDE (ATA) channel on-board for 1x DVD integrated in the<br />

Intel Southbridge ESB2-V<br />

* 8-port SAS controller on-board including IME (Integrated Mirroring Enhanced) offering<br />

the RAID level 1 without any additional costs.<br />

* RAID5 Intel® IOP332 I/O Processor ( codenamed Brockton ) on-board which uses the on-board<br />

LSI 1068 8-port SAS controller and which is enabled via an Upgrade Kit<br />

"SAS MegaRaid PCI Express ROMB". This kit contains a 256MB RAID cache memory<br />

( optional also 256MB with BBU ) and a so called iButton enable key.<br />

* Dual channel Gbit Ethernet LAN BroadCom 5715 on-board<br />

* Graphics controller integrated in iRMC (integrated Remote Management Controller)<br />

Resolution: 1280 x 1024 at 8bpp or 1024 x 768 at 16 bpp, 85Hz, VESA compatible<br />

* iRMC (integrated Remote Management Controller) onboard server management<br />

and graphics controller. Resolution: 1280 x 1024 at 8bpp or 1024 x 768 at 16 bpp<br />

External Interfaces:<br />

* 1x RS-232-C (serial, 9pin) (usable for BMC or OS or shared)<br />

* 1x optional RS-232-C (serial, 9-pin) - occupies PCI-slot 1!<br />

* 1x optional Centronics (parallel, 25 pin, EPP/ECP compatible) - occupies PCI-slot 5!<br />

* 1x keyboard (PS/2)<br />

* 1x mouse (PS/2)<br />

* 1x VGA (15 pin)<br />

* 4x USB 2.0 ( UHCI ) with 480MBit/s (2x external at the rear, 2x external at the frontside, no USB wakeup)<br />

* 2x LAN RJ45<br />

Cables:<br />

1. IDE cable for CD/DVD and floppy cable.<br />

2. Power cable<br />

Software:<br />

* ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView<br />

* Documentation engl. (multilingual on CD)<br />

A<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 6 of 21


System configurator and order-information guide<br />

A <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Cables included in basic unit<br />

Connections Cable <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong><br />

1. IDE CD/DVD and floppy ◦ ◦<br />

2. Power cable<br />

Rack version for 19'' racks with<br />

1 hot plug power supply module<br />

- Base memory of basic units selectable via<br />

base memory order codes<br />

Basic unit with<br />

- 1x 64-bit Intel Xeon (2 x 2 MB SLC) processor<br />

with 667/1066 MHz Frontside Bus (max. 2)<br />

Xeon 5050/3.0GHz/2x2M/667 S26361-K1024-V103<br />

Xeon 5060/3.2GHz/2x2M/1066 S26361-K1024-V104<br />

Xeon 5080/3.73GHz/2x2M/1066 S26361-K1024-V106<br />

Basic unit with<br />

- 1x 64-bit Intel Xeon (4 MB SLC) processor<br />

with 1066/1333 MHz Frontside Bus (max. 2)<br />

Xeon DP 5110 (1.6GHz/4M/1066)<br />

Xeon DP 5120 (1.86GHz/4M/1066)<br />

Xeon DP 5130 (2.00GHz/4M/1333)<br />

Xeon DP 5140 (2.33GHz/4M/1333)<br />

Xeon DP 5150 (2.66GHz/4M/1333)<br />

Xeon DP 5160 (3.00GHz/4M/1333)<br />

S26113-F453-E30<br />

2nd power supply 600W<br />

(hot plug) for redundancy For later conversion the following kit is available:<br />

occupies one bay for 1.) 1 power supply module 600W hot plug S26113-F453-L30<br />

hot plug power supply incl. power cord<br />

max. 1x per system<br />

S26361-F2621-E4<br />

Redundant Fans option<br />

4 single hot plug fans<br />

max. 1x per system<br />

B<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 7 of 21


System configurator and order-information guide<br />

B <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

<strong>PRIMERGY</strong> 19" Rack<br />

<strong>PRIMERGY</strong> PRIMECENTER-Rack<br />

"Rack-mounting ex factory"<br />

SNP:SY-F1647E301-P<br />

This service is to be ordered once<br />

Installation ex works for one<br />

per installable server/storage<br />

server or subsystem.<br />

subsystem, in order to get the<br />

Hereby the rack will be delivered<br />

server/storage subsystem<br />

completely pre-mounted and<br />

mounted into the <strong>PRIMERGY</strong> racks.<br />

all wired connections are tested Important notice ! In case of the 46 U <strong>PRIMERGY</strong> rack,<br />

With racks 12U, 24U, 38U: The mounting kit for <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> this service has to be ordered,<br />

Systems and components is included the basic version and to get the mounting kits and the<br />

will be delivered installed in the rack will be delivered with every <strong>RX300</strong> <strong>S3</strong> cables installed.<br />

With racks 46U:<br />

Systems and components<br />

will be delivered separately <strong>PRIMERGY</strong> 42/23U rack<br />

To be ordered only together with <strong>PRIMERGY</strong> Classic 19" rack is not supported<br />

a<br />

<strong>PRIMERGY</strong>-<br />

PRIMECENTER<br />

rack<br />

e . g . :<br />

S26361-K826-V10x<br />

refer configurator PC-rack<br />

max. 1x per system<br />

Section II Processor<br />

There are 2 processor sockets available.<br />

A dual-processor system requires a multi-processor operating system.<br />

Later upgrading to a dual-processor system is also possible.<br />

For a CPU extension the second CPU must be of identical type and clock rate.<br />

S26361-F3312-E300 S26361-F3312-E320 S26361-F3312-E373<br />

64-bit Intel Xeon 5050 64-bit Intel Xeon 5060 64-bit Intel Xeon 5080<br />

3.00GHz/667MHzFSB 3.20GHz/1066MHzFSB 3.73GHz/1066MHzFSB<br />

with 2x 2 MB SLC on Chip with 2x 2 MB SLC on Chip with 2x 2 MB SLC on Chip<br />

(SLC=Second Level Cache) (SLC=Second Level Cache) (SLC=Second Level Cache)<br />

and passive heat sink and passive heat sink and passive heat sink<br />

occupies socket for one CPU occupies socket for one CPU occupies socket for one CPU<br />

max. 1x per system max. 1x per system max. 1x per system<br />

C<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 8 of 21


System configurator and order-information guide<br />

C <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section III Memory<br />

- There are 8 memory slots for max. 32GB RAM ( Fully Buffered DIMM = FBD533 / PC2-4200F ) available<br />

( For explanation of following terms refer to section "Memory Configurations"<br />

- The memory area is divided into 2 branches with 2 channels each and 2 slots per channel<br />

- The first slot of each channel belongs to memory bank 1, the second slot belongs to memory bank 2<br />

- Each slot can optionally be equipped with 512MB, 1GB, 2GB or 4GB FBDIMM modules<br />

No mix of modules within one memory branch of bank1 or bank2 allowed.<br />

- Memory upgrade is only possible per branch with modul pairs<br />

( one pair per branch, max. two pairs / branch). )<br />

- For each basic unit bank 1 of the first branch has to be equipped with one memory pair,<br />

which has to be ordered with the ordercode of a "Base Memory"<br />

(either 2x512MB = 1GB, 2x1GB = 2GB, 2x2GB = 4GB or 2x4GB = 8GB)<br />

Note**: The price of the smallest 1GB FBD533 Base Memory is already included in the basic unit,<br />

The price of the other Base Memories is the Delta to the smallest 1GB FBD533 Base Memory<br />

So additional memory extensions (Upgrade Memory ) can still be configured up to three times<br />

for the standard market price.<br />

- For the function Memory Mirroring two identical memory module pairs regarding capacity<br />

are necessary in each branch of one memory bank. So following memory has to be ordered:<br />

1.) Minimum one time the same capacity like already is preinstalled in the basic unit has to be ordered<br />

2.) For addtitional memory 2x the same capacity has to be ordered<br />

- 4-way memory interleave technology for maximum performance is possible with<br />

2 memory module pairs in one memory bank (one pair per branch )<br />

- ECC with memory scrubbing and Chipkill is standard for <strong>RX300</strong> <strong>S3</strong>.<br />

See Note** above<br />

as soon as available<br />

S26361-F3313-B521 S26361-F3313-B522 S26361-F3313-B523 S26361-F3313-B524<br />

Base Memory 1GB Base Memory 2GB Base Memory 4GB Base Memory 8GB<br />

FBD533 / PC2-4200F FBD533 / PC2-4200F FBD533 / PC2-4200F FBD533 / PC2-4200F<br />

1x consisting of consisting of consisting of consisting of<br />

2 single rank modules 2 dual rank modules 2 dual rank modules 2 dual rank modules<br />

occupies one branch occupies one branch occupies one branch occupies one branch<br />

m a x . 1x per system m a x . 1x per system m a x . 1x per system m a x . 1x per system<br />

D<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 9 of 21


System configurator and order-information guide<br />

D <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

For the Memory Mirroring mode two identical memory modules pairs (branch 0 & 1) are necessary.<br />

( bank1 of branch 0 and 1 contain identical memory pairs )<br />

Therfore the following upgrade memory has to be ordered additionally:<br />

1.) Minimum one time the same capacity like the selected Base Memory of the basic unit =<br />

2.) For addtitional memory 2x the same capacity =<br />

The function Memory Mirroring can be configured per BIOS setup.<br />

For mirrored memory configurations the following items have to be considered:<br />

Capacity: 50% of the configured memory<br />

Availability: Maximum memory availability<br />

After non-correctable errors or too many correctable errors<br />

the Mirror takes over immediately and the system remains online.<br />

Performance: 2-way interleave only in mirror configurations,<br />

therefore potentially not max. performance<br />

In general it is recommended to use identical capacities over the branches / channels,<br />

regarding bank1 and bank 2 to ensure max. performance bandwidth. = = =<br />

bank 2<br />

FB-DIMM FB-DIMM FB-DIMM FB-DIMM<br />

bank 1<br />

FB-DIMM FB-DIMM FB-DIMM FB-DIMM<br />

channel 0 channel 1 channel 0 channel 1<br />

branch 0 branch 1<br />

Memory Controllers<br />

Only possible with FBD533 / PC2-4200F Base Memory<br />

as soon as available<br />

S26361-F3313-E521 S26361-F3313-E522 S26361-F3313-E523 S26361-F3313-E524<br />

Upgrade memory 1GB Upgrade memory 2GB Upgrade memory 4GB Upgrade memory 8GB<br />

FBD533 / PC2-4200F FBD533 / PC2-4200F FBD533 / PC2-4200F FBD533 / PC2-4200F<br />

with SDDC=chipkill support with SDDC=chipkill support with SDDC=chipkill support with SDDC=chipkill support<br />

consisting of consisting of consisting of consisting of<br />

2 single rank modules 2 dual rank modules 2 dual rank modules 2 dual rank modules<br />

occupies one branch occupies one branch occupies one branch occupies one branch<br />

max. 3x per system max. 3x per system max. 3x per system max. 3x per system<br />

Section IV Graphics<br />

Graphics controller integrated in iRMC (integrated Remote Management Controller)<br />

( 1280 x 1024 at 8bpp, 1024 x 768 at 16bpp, Resolution 85Hz )<br />

Other graphic cards are only possible in PCI bus by ordering via Customizing.<br />

E<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 10 of 21


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Following memory configurations are possible<br />

1.) Normal Mode<br />

Bank 2<br />

FB<br />

-DIMM<br />

FB<br />

-DIMM<br />

F B- DIMM<br />

F B- DIMM<br />

Bank 2<br />

Bank 1<br />

FB<br />

-DIMM<br />

FB<br />

-DIMM<br />

F B- DIMM<br />

F B- DIMM<br />

Bank 1<br />

Channel<br />

A<br />

Channel B Channel<br />

C<br />

Channel<br />

D<br />

Branch 0<br />

Branch 1<br />

Memory Controller<br />

(Blackford<br />

MCH)<br />

‣ Basically up to four different types of DIMMs pairs can be installed in Normal Mode.<br />

‣ The DIMMs of one pair must cover the same bank position on both channels of a branch.<br />

‣ DIMM pairs must be identical with respect to size, speed, and organization.<br />

‣ Within a branch memory DIMM pairs must be populated in bank order; Bank 1 first, Bank 2 second.<br />

‣ The two channels on each branch operate in lock step to increase FBD bandwidth.<br />

2.) Mirror Mode<br />

F<br />

B-DIMM FBD 2D<br />

Memory<br />

Population<br />

F<br />

B-DIMM FBD 1D<br />

F<br />

B-DIMM FBD 2C<br />

P h y s i c a l<br />

V i e w<br />

L o g i c a l V i e w<br />

FB-<br />

DIMM<br />

FBD 1C<br />

Mirroring<br />

FB-<br />

DIMM<br />

FBD 2B<br />

Bank 2<br />

FB - D F<br />

I M B-DIMM<br />

M ( S p a r e )<br />

F B - D F<br />

I M B-DIMM<br />

M ( S p a r e )<br />

F B - DIMM M ( M)<br />

S p a r e )<br />

FB - DIMM ( M Spare )<br />

)<br />

Bank 2<br />

FB-<br />

DIMM<br />

FBD 1B<br />

F B- DIMM<br />

FBD 2A<br />

Bank 1<br />

F B - DIMM<br />

FB - DIMM<br />

FB - DIMM (M)<br />

FB - DIMM (M)<br />

Bank 1<br />

F B- DIMM<br />

FBD 1A<br />

Mirroring<br />

C h A<br />

Memory<br />

ChB C h C<br />

Controller<br />

(Blackford<br />

MCH)<br />

Branch 0<br />

C h D<br />

Branch 1<br />

Channel<br />

A<br />

0<br />

C h a n n e l B 1<br />

C h a n n e l 2<br />

C<br />

C h a n n e l 3<br />

D<br />

Branch 0<br />

Branch 1<br />

Memory Controller<br />

( B l a c k f o r d M C H )<br />

‣ Basically up to two different types of DIMM pairs can be installed in Mirror Mode (one type in bank 1, one type in bank 2)<br />

‣ Mirroring requires both branches, since both branches contain identical images of memory data.<br />

‣ Both DIMM pairs in brach0 and branch1 of on bank must be identical with respect to size, speed, and organization.<br />

‣ Mirroring & branch interleaving are mutually exclusive of each o ther.<br />

‣ Within a bank memory DIMM pairs must be populated in branch order; Branch 0 first, mirrored DIMM pairs in Branch 1<br />

s e c o n d .<br />

F u j i t s u S i e m e n s C o m p u t e r s<br />

Enterprise Products <strong>PRIMERGY</strong> Server 11 of 21


System configurator and order-information guide<br />

E <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section V Accessible drives<br />

Setup <strong>RX300</strong> <strong>S3</strong> by ServerStart is supported with following configurations:<br />

no Floppy, no DVD, no CD:<br />

remote installation only ( PXE service & DHCP server required)<br />

built in CD/DVD or USB CD/DVD, no Floppy disk drive:<br />

UNC Network share reachable or USB Floppy connected<br />

built in Floppy or USB Floppy, no CD/DVD:<br />

USB CD/DVD connected<br />

Following USB devices can be used for local installation:<br />

One of the following USB devices must be used for integrating the drivers during installation<br />

process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:<br />

1 ) U S B D V D + - R W : S26391-F3152-L300<br />

Traveller III DVD DL super multi drive (USB cable included)<br />

2) FDD USB (external): S26391-F264-L226<br />

external USB FDD (USB cable included)<br />

3) USB Keyboard: S26381-K340-V120<br />

KBPC PX D, professional keyboard<br />

4) USB Mouse: S26381-K403-L100<br />

Optical Wheel Mouse<br />

5) USB Memorybird: S26391-F6046-L24<br />

Memorybird 1GB<br />

Additionally a monitor can be connected to the VGA 15-pin interface.<br />

(see section IX)<br />

S26361-F2557-E104<br />

S26361-F3059-E2<br />

LocalView Option Kit Floppy disk drive 0,5"<br />

1x - LCD Display with mountingkit Connector: 26pin<br />

- 2 x 20 char. incl. description (Ger/US)<br />

occupies FD-drive/LCD bay 0.5" * 3.5", anthracite bezel<br />

max. 1x per system max. 1x per system<br />

S26361-F3123-E1<br />

S26361-F3236-E1<br />

CD-RW / DVD drive 0.5" DVD-RW 8x super multi drive<br />

1x 24/24/24x / 8x ATAPI all formats, DUAL/DL, DVD-RAM<br />

CD-RW only with W2K, W3K, Linux only W2K, W3K and Linux<br />

0.5 x 5.25", anthracite bezel 0.5 x 5.25", anthracite bezel<br />

max. 1x per system max. 1x per system<br />

F<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 12 of 21


System configurator and order-information guide<br />

F <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section VI Hard disks drives<br />

There is a 8 port SAS controller on-board.<br />

Up to 6 SAS 3.5" hard disks can be configured also in mixed configuration.<br />

If the option "Backup drive" is configured only 4 bays for hard disks are available<br />

Hot replace is only possible with on-board RAID or IME.<br />

S26361-F3204-E536 S26361-F3204-E573 S26361-F3204-E514<br />

HD 36GB 15krpm 3.5" HD 73GB 15krpm 3.5" HD 146GB 15krpm 3.5"<br />

6x / 15.000rpm,


System configurator and order-information guide<br />

G <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section VII SCSI-/SAS-/Disk Array/ Fibre-Channel Controller<br />

On-board SAS-Controller for SAS-HDs and SATA HD`s<br />

The system is equipped with a eight channel SAS on-board controller and embedded "IME".<br />

IME (Integrated Mirroring Enhanced) offers the RAID levels 0, 1, 1E without any additional costs.<br />

IME is a RAID 0, 1 implementation, whereby RAID 1 can operate with an odd number of hard disks.<br />

Up to 6 hard disks including one hot spare HD are possible (limited by HHD slots in<br />

system). Administration of IME is possible with the LSI Global Array Manager (GAM).<br />

Windows2000/2003 as well as SUSE and RedHat Linux are supported (Restrictions refer to Software Configurator)<br />

The SAS IME solution supports 2 independent RAID volumes, one can contain SAS disks the other SATA disks.<br />

No additional components required.<br />

1x per <strong>RX300</strong> <strong>S3</strong><br />

Example with 3 HD`s:<br />

The on-board SAS-controller can be upgraded via the "MegaRaid PCI Express ROMB" upgrade kit to a full<br />

SAS RAID controller (RAID 0, 1, 5, 10, 50 ).<br />

The onbaord SAS controller supports the following configuration only:<br />

Six internal SAS or SATA II HD`s in the basic unit, but no optional tape!<br />

no support for external tapes (e.g. SX10)<br />

no support for external discs (e.g. SX30)<br />

1x per <strong>RX300</strong> <strong>S3</strong><br />

H<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 14 of 21


System configurator and order-information guide<br />

H <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

on-board SAS-RAID controller<br />

The system is equipped with an eight port SAS on-board RAID controller.<br />

RAID levels 0, 1, 10, 5 and 50 are supported and can be enabled by iButton plus cache<br />

The RAID controller supports HDDs on the 6 internal SAS ports. Tapes and optical devices (e.g. DVD) are not suported.<br />

Also there is no support of any external storage by this RAID solution.<br />

1x per <strong>RX300</strong> <strong>S3</strong><br />

S26361-F3205-E256<br />

S26361-F3205-E556<br />

MegaRaid ROMB SAS MegaRaid ROMB SAS<br />

Upgrade Kit Upgrade Kit<br />

includes iButton, 256MB Cache includes iButton, 256MB Cache<br />

with<br />

iTBBU<br />

max. 1x per system max. 1x per system<br />

PCI standard slot usage PCI low profile slot usage<br />

S26361-F2622-E4<br />

(included in basic unit)<br />

Standard PCI System with Low Profile System<br />

PCI-risercard option incl. PCI-cage 1x PCIe x8 low profile<br />

(for 3 PCI-standard cards, full height) 2x PCIe x4 low profile, hot plug PCI (mech. x8)<br />

1 Slot PCI-X 133MHz / 64 bit, long 2x PCI-X 64Bit/133MHz low profile<br />

2 Slots PCI-X 133MHz / 64 bit, short<br />

P<br />

Fibre Channel controllers for external storage systems and SCSI controllers for external backup drives<br />

S26361-F2399-E1 S26361-F3122-E1 S26361-F3097-E1<br />

SCSI 160 controller 2GBit/s FC Controller 2GBit/s FC controller<br />

Adaptec SCSI Card 29160 Emulex Qlogic<br />

1 channel: LVD + Fast/ Ultra (decoupl.)LP101 QLA2340<br />

3x , LVD connect. for HD, without cable 1 Cannel 2GBit/sec FC Controller 1 Cannel 2GBit/sec FC controller<br />

LP101 2x Fast/Ultra connect. for acc. drives LC Interface for 50um fiber LC Interface for 50um fiber<br />

64/66 PCI, min 180 mm includes CD with AutoPilot PCI-X 64Bit / 133MHz, 170mm<br />

int: Fast 50 pol oder Ultra HD68 PCI-X 64Bit / 133MHz, 170mm 3.3V and 5V tolerant signaling<br />

+ LVD HD68; ext: HD68(LVD) 3.3V / 5V tolerant signaling max. 3x per system<br />

S W : max. 2 per system<br />

max. 2x per system For Netware only<br />

2 controller are<br />

supported<br />

No mix and match of different Fibre Channel Controllers<br />

possible.<br />

All controllers for the connection of external storage system are delivered without cables.<br />

For the configuration of external cabling see the configurator for external storage system.<br />

3x, to be<br />

continued<br />

on<br />

next<br />

page<br />

For Fibre Channel SAN also other componets like switches, SFPs and optical wires are<br />

orderable (for details see price liste)<br />

I<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 15 of 21


System configurator and order-information guide<br />

I <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

3x, to be<br />

continued on 2-channel U320 ( LSI ) SCSI controller for Disk Array<br />

previous<br />

page<br />

S26361-F3006-E128<br />

Internal connection of PCI-SCSI-RAID<br />

2-channel RAID Controller U320 controllers to HD backplanes in the<br />

LSI<br />

system are not supported.<br />

320-2<br />

128MB SDRAM ECC Cache The cables for the connection from the<br />

default with TBBU subsystems (SX30) to the RAID Controllers<br />

plug: internal 2x HD68; see configurator SX30.<br />

external: 2x VHDCI<br />

without<br />

cable<br />

64/66 PCI controller, 180mm<br />

3.3V and 5V tolerant signaling<br />

max. 2x per system<br />

The fitting connection cables can be found in the<br />

configurator of the appropriate Storage Subsystem.<br />

J<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 16 of 21


System configurator and order-information guide<br />

P <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

SCSI-/ Fibre-Channel Controller Low Profile<br />

1 slot PCIe x8 low profile A PCIe x4 card can also be plugged in a PCIe x8 slot<br />

2 slots PCIe x4 low profile, hot plug PCI (mech. x8) A PCIe x8 card can also be plugged in a PCIe x4 slot (mech. x8)<br />

2 slots PCI-X 64Bit/133MHz low profile PCI-X and PCIe slots are not compatible!<br />

SCSI controllers for external backup drives<br />

S26361-F2737-E201<br />

SCSI 160 controller, lp<br />

Adaptec SCSI Card 29160LP<br />

1 channel U160 LVD<br />

only external connection<br />

64/66(32/33) PCI Low Profile<br />

ext: VHDCI, 68 pol., U160<br />

S W :<br />

max. 2x per system<br />

Fibre Channel Controller for external storage systems<br />

S26361-F3122-E201 S26361-F3306-E201 S26361-F3306-E202 S26361-F3097-E201<br />

2GBit/s FC Controller 4GBit/s FC controller 4GBit/s FC controller 2GBit/s FC Controller<br />

Emulex Emulex Emulex Qlogic<br />

LP101, low profile bracket LPe1150 LPe11002 QLA2340, PCI Low Profile<br />

3x 1 channel 2GBit/sec FC controller 1 channel 4GBit/sec FC Controller 2 channel 4GBit/sec FC Controller 1 channel 2GBit/sec FC controller<br />

LC Interface for 50um fiber LC Interface for 50um Fiber LC Interface for 50um Fiber LC Interface for 50um Fibre<br />

includes CD with AutoPilot PCI-E x4, 170mm PCI-E x4, 170mm PCI-X 64Bit / 133MHz, 170mm<br />

PCI-X 64Bit / 133MHz, 170mm 3.3V and 5V tolerant signaling<br />

3.3V / 5V tolerant signaling max. 3x per system max. 3x per system max. 2x per system<br />

max. 2 per system<br />

No mix and match of different Fibre Channel Controllers<br />

possible.<br />

All controllers for the connection of external storage system are delivered without cables.<br />

For the configuration of external cabling see the configurator for external storage system.<br />

For Fibre Channel SAN also other componets like switches, SFPs and optical wires are<br />

orderable (for details see price liste)<br />

L<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 17 of 21


System configurator and order-information guide<br />

J <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section VIII Communication / Network<br />

2-channel on-board LAN Controller<br />

Gigabit Ethernet Controller on-board Teaming: Failover, Load Balancing<br />

2-channel 1GBit BroadCom 5715 The Intel LAN Controllers 1000MF , 1000MT , 1000TX<br />

Server Adapter, BroadCom can be used with the on-board controller in Teaming Mode<br />

ext: for RJ 45-connector<br />

SW: AFT, VLAN, Fast Channel With Broadcom on-board Gigabit Ethernet adapters<br />

for teaming the Broadcom drivers must be used<br />

Two onboard LAN ports can likewise educate a team.<br />

Adapters with Teaming capability 10-1000TX /SX<br />

S26361-F3054-E1 S26361-F3053-E1 S26361-F3142-E1<br />

Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Controller 1000TX Gigabit Ethernet Controller 1000TX<br />

Eth. Ctrl 1x1Gbit PCI-X Pro/1000MF LC Eth Ctrl 1x1Gbit PCI-X Pro/1000MT Cu Eth Ctrl 1x1Gbit PCI32 PRO/1000GT Cu<br />

Intel PRO/1000 MF Server Adapter Intel PRO/1000 MT Server Adapter Intel Pro/1000 GT Desktop Adapter<br />

PCI-X (PCI64/133), min 165 mm PCI-X (PCI64/133) PCI 32 (33/66MHz),<br />

ext:LC-connector ext: for RJ45-connector, Cat 5 ext: for RJ45-connector, Cat 5<br />

max. 3x per system max. 3x per system max. 3x per system<br />

3x<br />

B) Dual Port LAN Adapter<br />

while s t o c k s l a s t<br />

S26361-F3011-E1<br />

Gigabit Ethernet Controller Dual 1000TX<br />

Eth Ctrl 2x1Gbit PCI-X PRO/1000MT Cu<br />

Intel Pro/1000MT Dual Port Server Ad.<br />

PCI-X<br />

(PCI64/133)<br />

ext: for RJ45-plug, Cat 5<br />

max. 1x per system<br />

Token Ring Adapters not supported<br />

S26361-F2610-E2<br />

X.25 Controller PCI<br />

Eicon S94, X.21, 5V/3.3V<br />

incl. 2x X.21 connection cable<br />

X.21-Interface<br />

max. 2x per system<br />

S26361-F3120-E2<br />

S26361-F3120-E3<br />

Parallel Port Option Serial Port Option<br />

Centronics<br />

RS-232-C<br />

Cable with 25-pin plug Cable with 9-pin plug<br />

2x for a Centronics Parallel Port for a 2nd RS-232-C Serial Port<br />

Interface<br />

Interface<br />

occupies PCI slot 5 or 8 or occupies PCI slot 5 or 8 or<br />

PCI slot 4 or 7 if occupied PCI slot 4 or 7 if occupied<br />

max. 1x per system max. 1x per system<br />

K<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 18 of 21


System configurator and order-information guide<br />

L <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Communication / Network Low Profile<br />

Teaming: Failover, Load Balancing<br />

2-channel on-board LAN Controller The Intel LAN Controllers 10/100TX. 1000SX , 1000TX<br />

Gigabit Ethernet Controller on-board can be used with the on-board controller in Teaming Mode<br />

2-channel 1GBit BroadCom 5715<br />

Server Adapter, BroadCom With Broadcom on-board Gigabit Ethernet adapters<br />

ext: for RJ 45-connector for teaming the Broadcom drivers must be used<br />

SW: AFT, VLAN, Fast Channel Two onboard LAN ports can likewise educate a team.<br />

1 slot PCIe x8 low profile A PCIe x4 card can also be plugged in a PCIe x8 slot<br />

2 slots PCIe x4 low profile, hot plug PCI (mech. x8) A PCIe x8 card can also be plugged in a PCIe x4 slot (mech. x8)<br />

2 slots PCI-X 64Bit/133MHz low profile PCI-X and PCIe slots are not compatible!<br />

Adapters with Teaming capability 10-1000TX /SX lp<br />

S26361-F3054-E201 S26361-F3053-E201 S26361-F3142-E201<br />

Gigabit Ethernet Contr. 1000SX lp Gigabit Ethernet Controller 1000TX lp Gigabit Ethernet Controller 1000TX lp<br />

Eth. Ctrl 1x1Gbit PCI-X Pro/1000MF LC lp Eth Ctrl 1x1Gbit PCI-X Pro/1000MT Cu lp Eth Ctrl 1x1Gbit PCI32 PRO/1000GT Cu lp<br />

Intel PRO/1000 MF Server Adapter Intel PRO/1000 MT Server Adapter Intel Pro/1000 GT Desktop Adapter<br />

PCI-X (PCI64/133), min 165 mm PCI-X (PCI64/133) PCI 32 (33/66MHz),<br />

ext:LC-connector ext: for RJ45-connector, Cat 5 ext: for RJ45-connector, Cat 5<br />

max. 2x per system max. 2x per system max. 2x per system<br />

4x<br />

Dual Port Adapter 1000TX lp<br />

while s t o c k s l a s t as soon as available<br />

S26361-F3011-E201<br />

S26361-F3228-E201<br />

Gigabit Ethernet Controller Dual 1000TX lp Gigabit Ethernet Controller Dual 1000TX lp<br />

Eth Ctrl 2x1Gbit PCI-X PRO/1000MT Cu lp Eth Ctrl 2x1Gbit PCIe PRO/1000PT Cu lp<br />

Intel Pro/1000MT Dual Port Server Ad. Intel Pro/1000PT dual Server Adapter<br />

PCI-X (PCI64/133), Low Profile PCIe x4, Low Profile<br />

ext: for RJ45-plug, Cat 5 ext: for RJ45-plug, Cat 5<br />

max. 2x per system max. 3x per system<br />

S26361-F3120-E2<br />

S26361-F3120-E3<br />

Parallel Port Option Serial Port Option<br />

Centronics<br />

RS-232-C<br />

Cable with 25-pin plug Cable with 9-pin plug<br />

2x for a Centronics Parallel Port for a 2nd RS-232-C Serial Port<br />

Interface<br />

Interface<br />

occupies PCI slot 5 or 8 or occupies PCI slot 5 or 8 or<br />

PCI slot 4 or 7 if occupied PCI slot 4 or 7 if occupied<br />

max. 1x per system max. 1x per system<br />

M<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 19 of 21


System configurator and order-information guide<br />

K / M <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Section IX System Management Products (RemoteView)<br />

as soon as available<br />

S26361-F1790-E240<br />

Integrated RSB advanced pack<br />

integrated remote management controller<br />

activation key for<br />

graphical console redirection<br />

and remote media redirection<br />

max. 1x per system<br />

(see section V)<br />

S26361-F2557-E104<br />

S26361-F3059-E2<br />

LocalView Option Kit Floppy disk drive 0,5"<br />

1x - LCD Display with mountingkit Connector: 26pin<br />

- 2 x 20 char. incl. description (Ger/US)<br />

occupies FD-drive/LCD bay 0.5" * 3.5", anthracite bezel<br />

max. 1x per system max. 1x per system<br />

Section X Miscellaneous<br />

Section XI Country specific power cord<br />

Options and other peripherals<br />

For other options, refer to separate "Product specific options"<br />

These options are supplied lose with the shipment<br />

For suitable peripherals for this product, please refer to the section "Peripherals/communication"<br />

Country specific power cords are not required for rack versions, except for USA&Canada.<br />

Power cords are shipped in a rack version with inlet connector for non-heating apparatus.<br />

Description in englisch. Both included in basic unit.<br />

(1x with Standard PSU, 2x with hot plug upgrade)<br />

T26139-Y1742-E10 USA, Canada<br />

For shipments to USA&Canada, you have to order<br />

one power cord (1,8m, grey) per power supply.<br />

End <strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong><br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 20 of 21


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>RX300</strong> <strong>S3</strong> Status 2006-04-24<br />

Change Report<br />

Date Order number Changes<br />

2006-04-03 First draft<br />

Fujitsu Siemens Computers<br />

Enterprise Products <strong>PRIMERGY</strong> Server 21 of 21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!