5. Food probe Warning – After a Chill cycle is started in Probe mode, the<br />

unit continuously checks the Food Probe temperatures for a certain<br />

time (this time is Food Probe Warning Delay, low level programming).<br />

If during this time any Food Probe gives a reading > (Probe<br />

Temperature + Food Probe Warning Threshold), then an alarm is<br />

generated. However, unit continues to work normally, as this may be<br />

intentional on the part of the user (unused probe left “hanging” in the<br />

blast chiller). The display scrolls ‘FOOD PROBE WARNING’. Error<br />

LED lights up and buzzer sounds until Stop button is pressed. Unit<br />

keeps operating normally.<br />

6. Communications Error – If the ECM-1 cannot communicate with an<br />

ECM-3 an alarm is generated. The display scrolls ‘INTERNAL<br />

COMMUNICATION ERROR’. Error LED lights up and buzzer<br />

sounds until Stop button is pressed. Refrigeration unit continues<br />

working normally, but termination can only be time based (no Probes)<br />

and fan remains on all the time.<br />