5. Food probe Warning – After a Chill cycle is started in Probe mode, the<br />
unit continuously checks the Food Probe temperatures for a certain<br />
time (this time is Food Probe Warning Delay, low level programming).<br />
If during this time any Food Probe gives a reading > (Probe<br />
Temperature + Food Probe Warning Threshold), then an alarm is<br />
generated. However, unit continues to work normally, as this may be<br />
intentional on the part of the user (unused probe left “hanging” in the<br />
blast chiller). The display scrolls ‘FOOD PROBE WARNING’. Error<br />
LED lights up and buzzer sounds until Stop button is pressed. Unit<br />
keeps operating normally.<br />
6. Communications Error – If the ECM-1 cannot communicate with an<br />
ECM-3 an alarm is generated. The display scrolls ‘INTERNAL<br />
COMMUNICATION ERROR’. Error LED lights up and buzzer<br />
sounds until Stop button is pressed. Refrigeration unit continues<br />
working normally, but termination can only be time based (no Probes)<br />
and fan remains on all the time.<br />