Pump Data Sheet - <strong>Patterson</strong> 60 Hz Pumps<br />
Company: <strong>Patterson</strong> Pump Company<br />
Name:<br />
Date: 12/16/20<strong>11</strong><br />
Pump:<br />
Size: 18x14 MAB-C<br />
Type: HSC<br />
Synch speed: 1200 rpm<br />
Speed: <strong>11</strong>80 rpm<br />
Dia: 21.1875 in<br />
Curve: 14MAB-C Impeller: C-5762<br />
Specific Speeds: Ns: 2043<br />
Nss: ---<br />
Dimensions:<br />
Pump Limits:<br />
Suction: 18 in<br />
Discharge: 14 in<br />
Temperature: 200 °F Power: ---<br />
Pressure: 175 psi g Eye area: ---<br />
Sphere size: 2.125 in<br />
Pump Selection Warnings:<br />
Secondary operating point is not within the selection window.<br />
Search Criteria:<br />
Flow: 6944 US gpm<br />
Head: 179 ft<br />
Secondary Operating Point: 8333 US gpm, 100 ft<br />
Fluid:<br />
Water Temperature: 68 °F<br />
Density: 62.32 lb/ft³<br />
Vapor pressure: 0.3391 psi a<br />
Viscosity: 0.9946 cP<br />
Atm pressure: 14.7 psi a<br />
NPSHa: ---<br />
Motor:<br />
Standard: ---<br />
Enclosure: ---<br />
Sizing criteria: Max Power on Design Curve<br />
---<br />
Speed: ---<br />
Frame: ---<br />
Flow:<br />
Head:<br />
---- Data Point ----<br />
6944 US gpm<br />
179 ft<br />
Eff: 88%<br />
Power:<br />
NPSHr:<br />
357 hp<br />
17.8 ft<br />
---- Design Curve ----<br />
Shutoff head:<br />
Shutoff dP:<br />
Min flow:<br />
BEP:<br />
208 ft<br />
90 psi<br />
2792 US gpm<br />
89.1% @ 7976 US gpm<br />
NOL power:<br />
382 hp @ 103<strong>11</strong> US gpm<br />
-- Max Curve --<br />
Max power:<br />
541 hp @ <strong>11</strong>547 US gpm<br />
Head - ft<br />
250<br />
<strong>22</strong>5<br />
200<br />
175<br />
150<br />
125<br />
100<br />
<strong>23</strong>.5 in<br />
<strong>22</strong> in<br />
21.1875 in<br />
20.5 in<br />
73<br />
73<br />
80<br />
85<br />
88<br />
89<br />
89<br />
88<br />
80<br />
250 hp85 89.1<br />
85<br />
88 300 hp<br />
88<br />
85<br />
80<br />
80<br />
75<br />
40<br />
100<br />
200<br />
300<br />
400<br />
500<br />
600<br />
700<br />
800<br />
900<br />
1000<br />
<strong>11</strong>00<br />
1200<br />
Performance Evaluation:<br />
NPSHr - ft<br />
20<br />
0<br />
100 200 300 400 500 600 700 800 900 1000 <strong>11</strong>00 1200<br />
US gpm x10<br />
In accordance with the Hydraulic Institute Standards, pump is guaranteed for one set of conditions. Performance<br />
guarantees are based on shop test and when handling clear, cold, fresh water at sea level and at a temperature no<br />
greater than 85 degrees F. Suction lift must not exceed that shown on curve.<br />
Flow Speed Head Efficiency Power NPSHr<br />
US gpm rpm ft % hp ft<br />
8333 <strong>11</strong>80 158 89 374 21.2<br />
6944 <strong>11</strong>80 179 88 357 17.8<br />
5555 <strong>11</strong>80 193 83.6 3<strong>23</strong> 14.8<br />
4166 <strong>11</strong>80 200 75.7 277 12.4<br />
2778 <strong>11</strong>80 --- --- --- ---<br />
PDI PUMP SELECTION 10.6.0.0 Selected from catalog: <strong>Patterson</strong> Pumps 60HZ Vers: 1.2