Pump Data Sheet - <strong>Patterson</strong> 60 Hz Pumps<br />

Company: <strong>Patterson</strong> Pump Company<br />

Name:<br />

Date: 12/16/20<strong>11</strong><br />

Pump:<br />

Size: 18x14 MAB-C<br />

Type: HSC<br />

Synch speed: 1200 rpm<br />

Speed: <strong>11</strong>80 rpm<br />

Dia: 21.1875 in<br />

Curve: 14MAB-C Impeller: C-5762<br />

Specific Speeds: Ns: 2043<br />

Nss: ---<br />

Dimensions:<br />

Pump Limits:<br />

Suction: 18 in<br />

Discharge: 14 in<br />

Temperature: 200 °F Power: ---<br />

Pressure: 175 psi g Eye area: ---<br />

Sphere size: 2.125 in<br />

Pump Selection Warnings:<br />

Secondary operating point is not within the selection window.<br />

Search Criteria:<br />

Flow: 6944 US gpm<br />

Head: 179 ft<br />

Secondary Operating Point: 8333 US gpm, 100 ft<br />

Fluid:<br />

Water Temperature: 68 °F<br />

Density: 62.32 lb/ft³<br />

Vapor pressure: 0.3391 psi a<br />

Viscosity: 0.9946 cP<br />

Atm pressure: 14.7 psi a<br />

NPSHa: ---<br />

Motor:<br />

Standard: ---<br />

Enclosure: ---<br />

Sizing criteria: Max Power on Design Curve<br />

---<br />

Speed: ---<br />

Frame: ---<br />

Flow:<br />

Head:<br />

---- Data Point ----<br />

6944 US gpm<br />

179 ft<br />

Eff: 88%<br />

Power:<br />

NPSHr:<br />

357 hp<br />

17.8 ft<br />

---- Design Curve ----<br />

Shutoff head:<br />

Shutoff dP:<br />

Min flow:<br />

BEP:<br />

208 ft<br />

90 psi<br />

2792 US gpm<br />

89.1% @ 7976 US gpm<br />

NOL power:<br />

382 hp @ 103<strong>11</strong> US gpm<br />

-- Max Curve --<br />

Max power:<br />

541 hp @ <strong>11</strong>547 US gpm<br />

Head - ft<br />

250<br />

<strong>22</strong>5<br />

200<br />

175<br />

150<br />

125<br />

100<br />

<strong>23</strong>.5 in<br />

<strong>22</strong> in<br />

21.1875 in<br />

20.5 in<br />

73<br />

73<br />

80<br />

85<br />

88<br />

89<br />

89<br />

88<br />

80<br />

250 hp85 89.1<br />

85<br />

88 300 hp<br />

88<br />

85<br />

80<br />

80<br />

75<br />

40<br />

100<br />

200<br />

300<br />

400<br />

500<br />

600<br />

700<br />

800<br />

900<br />

1000<br />

<strong>11</strong>00<br />

1200<br />

Performance Evaluation:<br />

NPSHr - ft<br />

20<br />

0<br />

100 200 300 400 500 600 700 800 900 1000 <strong>11</strong>00 1200<br />

US gpm x10<br />

In accordance with the Hydraulic Institute Standards, pump is guaranteed for one set of conditions. Performance<br />

guarantees are based on shop test and when handling clear, cold, fresh water at sea level and at a temperature no<br />

greater than 85 degrees F. Suction lift must not exceed that shown on curve.<br />

Flow Speed Head Efficiency Power NPSHr<br />

US gpm rpm ft % hp ft<br />

8333 <strong>11</strong>80 158 89 374 21.2<br />

6944 <strong>11</strong>80 179 88 357 17.8<br />

5555 <strong>11</strong>80 193 83.6 3<strong>23</strong> 14.8<br />

4166 <strong>11</strong>80 200 75.7 277 12.4<br />

2778 <strong>11</strong>80 --- --- --- ---<br />

PDI PUMP SELECTION 10.6.0.0 Selected from catalog: <strong>Patterson</strong> Pumps 60HZ Vers: 1.2