8 Electrical<br />

The VORTEX Pro External module<br />

requires a 230/240 V ~ 50 Hz supply. It<br />

must be protected by a 5 Amp fuse.<br />

Refer to Figures 8-1 to 8-4 for typical<br />

control system wiring diagrams.<br />

Refer to Figure 8-5 for boiler internal<br />

wiring diagram.<br />

!<br />

WARNING<br />

The VORTEX Pro External module<br />

contains electrical switching<br />

equipment and must be earthed.<br />

The supply must be fused at 5 Amp<br />

and there must only be one common<br />

isolator for the boiler and control system,<br />

providing complete electrical isolation.<br />

A fused double pole switch or a<br />

fused three pin plug and shuttered<br />

outlet socket should be used for the<br />

connection.<br />

The power supply cable should be at<br />

least 0.75 mm² PVC as specified in BS<br />

6500, Table 16.<br />

All the wiring and supplementary earth<br />

bonding external to the boiler must be in<br />

accordance with the current I.E.E. Wiring<br />

Regulations.<br />

Any room thermostat or frost thermostat<br />

used must be suitable for use on mains<br />

voltage.<br />

The boiler requires a permanent mains<br />

supply, do not interrupt it with any<br />

external time control.<br />

In the event of an electrical fault after<br />

installation of the boiler, the following<br />

electrical system checks must be carried<br />

out:<br />

• Short circuit<br />

• Polarity<br />

• Earth continuity<br />

• Resistance to earth.<br />

8.1 Connecting the Power Supply<br />

!<br />

A Test switch is fitted to the control panel<br />

(see Figure 1-1) to allow the boiler to be<br />

test-fired. When On, the switch by-passes<br />

the external control system.<br />

It is recommend that the boiler should be<br />

connected to a switched mains power<br />

supply from a programmer or control<br />

system. If a <strong>Grant</strong> remote programmer is<br />

used, a permanent 240 V mains supply<br />

(fused at 5 Amp) must be taken to the<br />

boiler. A three core cable is required to<br />

connect the boiler terminal block to the<br />

live supply. Refer to Figures 8-1 to 8-4 for<br />

typical control system wiring diagrams.<br />

The procedure is:<br />

NOTE<br />

1. Undo the three screws and remove<br />

the lefthand cover from the control<br />

panel to gain access to the boiler<br />

terminal block.<br />

2. Pass the mains power supply<br />

cable through the cable grommet<br />

in the control panel, through the<br />

cable clamp and connect to the<br />

terminal block as follows:-<br />

Brown to live (terminal 2)<br />

Blue to mains neutral (terminal 3)<br />

Green/Yellow to mains earth<br />

(terminal 4)<br />

3. Refer to Figures 8-1 to 8-4 for<br />

a typical control system wiring<br />

diagrams.<br />

4. If the circulating pump is to be<br />

fitted within the boiler enclosure,<br />

the pump live must be connected<br />

to terminal 7 of the boiler terminal<br />

block.<br />

Pass the pump power supply<br />

cable through the cable grommet<br />

in the control panel, through the<br />

cable clamp and connect to the<br />

terminal block as follows:-<br />

Brown to live (terminal 7)<br />

Blue to mains neutral (terminal 9)<br />

Green/Yellow to earth (terminal<br />

Connecting the pump in this way<br />

allows it to be isolated using the<br />

isolating switch fitted in the boiler<br />

control panel, for servicing or<br />

maintenance work.<br />

5. Ensure that the cable clamp is<br />

tightened and that all cables are<br />

secure and all external wiring is<br />

adequately supported.<br />

6. Replace the cover on the control<br />

panel, with the yellow warning<br />

label facing outwards and secure<br />

with the three screws.<br />

Do not switch on the electricity supply<br />

to the External module at this stage.<br />

8.2 Frost Protection<br />

External Modules are supplied with<br />

a factory fitted frost protection<br />

thermostat, located inside the boiler<br />

control panel. This is pre-wired to the<br />

boiler electrical system and factory set<br />

to 2°C.<br />

For total system protection against<br />

freezing, particularly during extended<br />

periods without electrical power,<br />

<strong>Grant</strong> recommend the use of a<br />

combined heating system antifreeze<br />

and corrosion inhibitor, used in<br />

accordance with the manufacturer's<br />

instructions.<br />

Electrical<br />

23