<strong>Grant</strong> Engineering (<strong>UK</strong>) Limited<br />

Hopton House, Hopton Industrial Estate, Devizes, Wiltshire SN10 2EU<br />

Tel: 01380 736920 Fax: 01380 736991<br />

Email: sales@grantuk.com www.grantuk.com<br />

This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or<br />

appearances are changed in the interests of continued product improvement.<br />

All goods sold are subject to our official Conditions of Sale, a copy of which may be obtained on application.<br />

© <strong>Grant</strong> Engineering (<strong>UK</strong>) Limited 2012. No part of this manual may be reproduced by any means without prior written consent.<br />

2<br />

Service Log<br />

For use with Kerosene* only.<br />

After installing the boiler leave these<br />

instructions with the User.<br />

Service Log<br />

It is recommended that the boiler should be regularly serviced, at least once a year,<br />

and the details entered in the Boiler Handbook by the service engineer.<br />

This appliance is deemed a controlled<br />

service and specific regional statutory<br />

requirements may be applicable.<br />

*Operation on Bio-fuel<br />

All <strong>Grant</strong> Vortex Pro condensing boilers,<br />

manufactured since May 2011, are suitable<br />

for operation on both standard kerosene<br />

(Class C2 to BS2869) and also bio-kerosene<br />

– up to a 30% blend (B30K).<br />

All burner settings and nozzle sizes (as<br />

detailed in Section 2.3 of this manual)<br />

are correct for both standard kerosene<br />

and bio-kerosene (B30K).<br />

In order to operate this boiler on biokerosene<br />

it will be necessary to take<br />

the following actions:<br />

a) Use a bio-kerosene (B30K)<br />

compatible flexible oil line in place of<br />

the oil line supplied with this boiler.<br />

b) Have your oil storage tank and oil<br />

supply line (including all pipework,<br />

sight gauges, filters, isolating valves,<br />

fire valves, de-aeration devices, etc.)<br />

checked for their compatibility with<br />

bio-kerosene (B30K).<br />

Where necessary some, or all, of these<br />

items may have to be replaced with a<br />

bio-kerosene compatible alternative.<br />

c) Check the suitability of the flue system<br />

with <strong>Grant</strong> <strong>UK</strong>.<br />

d) Use only bio-kerosene (B30K) that<br />

conforms to OPS24.<br />

IMPORTANT<br />

Under no circumstances should the<br />

boiler be used with bio-kerosene without<br />

the above actions being taken first.