12 Fault Finding<br />
12.1 Boiler Fault Finding<br />
Always isolate the electricity supply to the boiler before working on the boiler.<br />
Fault<br />
Boiler will not start:<br />
Remedies<br />
1 No fuel supply.<br />
2 No electricity supply.<br />
3 Burner not starting - fuel and<br />
electricity supplies present.<br />
4 Burner lights but goes to lock-out.<br />
Boiler works but:<br />
5 Visible smoke from flue or high<br />
smoke number.<br />
6 Burner pulses.<br />
7 Flame slow to stabilise<br />
during start up.<br />
8 Water temperature low.<br />
9 Boiler operating on overheat<br />
thermostat.<br />
10 Oil odours.<br />
11 Combustion fumes smell.<br />
Ensure that an adequate supply of fuel is available and that the fuel supply valve is open.<br />
Check the condition of the fuel filter, clean if necessary.<br />
Ensure fuel supply is reaching burner and vent pump.<br />
Ensure electricity supply to the boiler is switched on and that all controls are calling for heat.<br />
Ensure that the overheat thermostat has not tripped, reset if necessary.<br />
Check that a mains supply is present at the burner terminal block.<br />
If not, check the boiler and overheat thermostat.<br />
Press the reset button on the burner control box if it is lit.<br />
Refer to burner fault finding charts.<br />
If the flame is unstable, check the combustion settings.<br />
Refer to burner fault finding charts.<br />
Insufficient air supply - check the air damper setting and the condition of the fan.<br />
Check ventilation openings in door are clear, see Section 9.6.<br />
Check the nozzle size and type.<br />
Fuel pressure may be too high - check and adjust.<br />
Insufficient air supply - check the air damper setting and the condition of the fan.<br />
Check ventilation openings in door are clear, see Section 9.6.<br />
Check the nozzle size and type.<br />
Insufficient air supply - check the air damper setting and the condition of the fan.<br />
Check ventilation openings in door are clear, see Section 9.6.<br />
Check the nozzle size and type.<br />
Fuel pressure may be too low - check and adjust.<br />
Insufficient draught - clean boiler heat exchanger and check condition of flue.<br />
Undersize nozzle and/or low fuel pressure.<br />
Check condition of boiler heat exchanger and clean if necessary.<br />
Check the boiler thermostat.<br />
Check the combustion settings.<br />
Check the condition of the fuel filter.<br />
Faulty boiler thermostat. No circulation, check circulating pump. Check for air lock.<br />
Check all fuel line connections, remake as necessary.<br />
Check boiler cleaning cover and seal are correctly fitted.<br />
Check burner is correctly fitted onto flange.<br />
Check flue is correctly sealed into flue outlet of boiler.<br />
Check the condensate pipe and trap are operating correctly.<br />
Fault Finding<br />
37