4User <strong>Instructions</strong><br />
User <strong>Instructions</strong><br />
Introduction<br />
This User Guide is intended to assist<br />
the User in the operation of the <strong>Grant</strong><br />
VORTEX Pro External modules. The<br />
engineers manual for the installation and<br />
maintenance of this boiler is attached to<br />
the reverse of these instructions<br />
The following special text formats are<br />
used in this manual for the purposes<br />
listed below.<br />
!<br />
Warning of possible human injury as<br />
a consequence of not following the<br />
instructions in the warning.<br />
!<br />
WARNING<br />
NOTE<br />
Note text. Used for emphasis or<br />
information not directly concerned<br />
with the surrounding text but of<br />
importance to the reader.<br />
About your boiler<br />
The boiler is fully automatic once<br />
switched on, providing central heating<br />
(and also heating your domestic hot<br />
water if you have a hot water cylinder<br />
fitted). An illuminated On/Off switch, see<br />
Figure 1, is fitted to the External modules<br />
which lights when the boiler is switched<br />
on, but does not necessarily indicate the<br />
burner is firing.<br />
Boiler Controls<br />
To gain access to the External module<br />
controls, remove the front panel by<br />
turning the handle and withdrawing<br />
it forwards at the bottom.<br />
Lighting your Boiler<br />
The lighting procedure is:<br />
1. Ensure that there is sufficient fuel, of<br />
the correct type, in the supply tank<br />
and all fuel supply valves are open.<br />
The water supply is on. The electricity<br />
supply to the boiler is off. The boiler<br />
On/Off switch is set to OFF (the<br />
neon in the switch is not alight). The<br />
test switch is set to OFF. The room<br />
thermostat (if fitted) is at the desired<br />
setting. The boiler thermostat is set<br />
to the required setting.<br />
2. Switch on the electricity supply to<br />
the boiler.<br />
3. Set the boiler On/Off switch to ON.<br />
The neon in the switch lights when it<br />
is in the on position.<br />
4. The boiler will now light<br />
automatically.<br />
If your Boiler Fails to Light<br />
Make the following checks:<br />
1. Check that the boiler On/Off switch<br />
is ON.<br />
2. Check that any remote programmer<br />
(if fitted) is working and is in an 'on'<br />
period.<br />
3. Check that all thermostats are set to the<br />
desired setting and are calling for heat.<br />
DANGER THERE IS MORE THAN ONE LIVE SUPPLY TO<br />
THIS CONTROL PANEL<br />
BOILER ON/OFF SWITCH<br />
ISOLATES PUMP (IF WIRED<br />
INTO BOILER CONTROL<br />
PANEL) & BURNER ONLY.<br />
THIS COVER IS TO BE<br />
REMOVED BY QUALIFIED<br />
PERSONNEL ONLY<br />
DO NOT REMOVE COVER<br />
WITHOUT ISOLATING<br />
SWITCHED LIVE AND<br />
FROST 'STAT<br />
PERMANENT LIVE<br />
TEST SWITCH<br />
OVERIDES SYSTEM<br />
CONTROLS TO<br />
OPERATE BOILER<br />
PRO EXTERNAL<br />
TEST<br />
SWITCH<br />
OFF<br />
BOILER<br />
OFF<br />
REFER TO WIRING DIAGRAM IN MANUAL<br />
HEATING<br />
THERMOSTAT<br />
OVERHEAT<br />
RESET<br />
Control Panel<br />
DANGER THERE IS MORE THAN ONE LIVE SUPPLY TO<br />
THIS CONTROL PANEL<br />
TEST<br />
SWITCH<br />
OFF<br />
BOILER<br />
OFF<br />
HEATING<br />
THERMOSTAT<br />
OVERHEAT<br />
RESET<br />
ON ON<br />
REFER TO WIRING DIAGRAM IN MANUAL<br />
Boiler front<br />
panel removed<br />
Figure 1: Boiler controls<br />
Test<br />
switch<br />
Boiler<br />
On/Off switch<br />
‘Lock-out’ reset button<br />
Boiler<br />
thermostat<br />
Overheat thermostat<br />
reset button<br />
(under screw cover)<br />
ON ON