Hand magnetizing tools<br />
SERIE HANSA-230<br />
UM15 UM5 UM9 UM10 UM8<br />
UM 5 UM 8 UM 9 UM 10 UM 15 crossyoke<br />
Art.-Nr. 131.002.018 131.002.020 131.002.024 131.002.026 131.002.028 131.016.100<br />
Pol distance<br />
(mm) 162 170 170 135 95 - 250 120 / 120<br />
Pol magnetizing<br />
area (mm) 27 x 25 25 x 25 25 x 25 25 x 25 25 x 25 25 x 25<br />
Outer<br />
dimensions<br />
(mm) 235x145x47 265x163x50 250x130x46 210 x 110 255 x 173 235x180x320<br />
Tangential<br />
fieldstrength 32 40 35 35 21 32<br />
A/cm (DIN<br />
54131-2)<br />
Connecting<br />
cable (m) 3 3,5 3 3 3 5<br />
Voltage V 230 230 230 230 230 230/42<br />
Protection class IP 65 IP 65 IP 65 IP 65 IP 65 IP 54<br />
Pull of strengtht 130 130 130 90 50 >300<br />
9934-3; 2002<br />
(N)<br />
weight (kg) 3,0 3,3 2,9 2,2 3,2 9,2<br />
Flaw Finder Type A<br />
Art.-Nr. 131.001.010<br />
TB 10 weight lifting test block<br />
The TB 10 serves test for change-, direct<br />
current and permanent magnet. The block<br />
weight is marked on each block and is<br />
provable by NIST.<br />
Flaw Finder Type N<br />
Art.-Nr. 131.001.022<br />
Lifting power: >30kg, field strength:>15Oe (pole<br />
distance 150mm)<br />
Outer diameter: 32mm, hight of the magnet:<br />
32mm, length of the junction cable: 400mm,<br />
weight without case: appr. 900g<br />
This instrument especially proved for effective in<br />
<strong>testing</strong> small parts and welds.<br />
We certify that the permanent magnet has lifting<br />
force ≥265N (27kg) with a spacing between legs<br />
(minimum lifting force according ASTM E 709 is<br />
225N (22,5kg) with a 100 to 150 spacing between<br />
legs.The permanent magnet was created and <strong>testing</strong><br />
according to ASTM E 709 + ASTM E 1444.<br />
11