SECTION 3: CIRCUIT REQUIREMENTS<br />

Amperage Draw<br />

Plug-Type<br />

The Model G0550/G0551 motor is wired to operate<br />

at 220V only. The planer motors draw the following<br />

amperage:<br />

Amperage Draw<br />

G0550 2 HP..........................................12 Amps<br />

G0551 3 HP..........................................18 Amps<br />

We recommend using a NEMA-style 6-15 plug<br />

and outlet with the G0550 as shown in Figure 1a<br />

and an L6-20 plug and outlet for the G0551 as<br />

shown in Figure 1b. You may also “hard-wire”<br />

the planer directly to your panel, provided you<br />

place a disconnect near the machine. Check the<br />

electrical codes in your area for specifics on<br />

wiring requirements.<br />

Circuit Breaker<br />

Use the following guidelines when choosing a circuit<br />

breaker (circuit breakers rated any higher are<br />

not adequate to protect the circuit):<br />

Circuit Breaker<br />

G0550 ........................................15 Amp, 2 Pole<br />

G0551 ........................................20 Amp, 2 Pole<br />

Figure 1a. NEMA 6-15 plug and receptacle.<br />

Figure 1b. NEMA L6-20 plug and receptacle.<br />

-6- G0550/G0551 15" Planer