Saab Rosemount TankRadar<br />

<strong>FBM</strong> <strong>2180</strong><br />

Chapter 2 <strong>Installation</strong><br />

<strong>Installation</strong> <strong>Instruction</strong><br />

308019E, Edition 1<br />

May 2006<br />

2. <strong>Installation</strong><br />

2.1 Power Supply<br />

Use adapter 90-264 V ac/9 V dc 1.5 A for RS232 communication.<br />

DO NOT use external power supply when the modem is connected to the<br />

USB port. The USB interface itself supports power to the <strong>FBM</strong><strong>2180</strong><br />

modem.<br />

Power supply (polarity independent)<br />

(RS 232 communication only)<br />

2.2 TRL/2 Bus<br />

Use single twisted preferably shielded pair cable. Individual shielding is<br />

mandatory if parallel buses run in the same cable. Polarity independent.<br />

Recommended wiring length:<br />

Cable dimension<br />

AWG 20 (0.50 mm 2 )<br />

AWG 18 (0.75 mm 2 )<br />

Maximum Length<br />

3000 m<br />

4000 m<br />

TRL/2 Bus<br />