<strong>USDT</strong> <strong>3004</strong><br />
4.2 Adjustment channels<br />
System layout selection<br />
Arr:<br />
System layout selection.<br />
Adjustment range: 1 ... 3<br />
Factory setting: 1<br />
Security enquiry:<br />
In this channel, a pre-defined system layout can be selected.<br />
Each system layout has a set of pre-programmed settings<br />
that can be individually changed.<br />
If the system layout selection is changed later on, all adjustments<br />
made in the other channels will be lost. Therefore,<br />
changing the system layout is always followed by a security<br />
enquiry.<br />
Only confirm the security enquiry if you are sure that<br />
you wish to change the system layout selection!<br />
ÎÎTo confirm the security enquiry, press button 3<br />
∆T-regulation<br />
DT O:<br />
Switch-on temperature diff.<br />
Adjustment range: 2.0 ... 40.0°Ra<br />
[1.0 ... 20.0 K]<br />
in steps of 1 °Ra [0.5 K]<br />
Factory setting: 12.0°Ra<br />
[6.0 K]<br />
DT F:<br />
Switch-off temperature diff.<br />
Adjustment range: 1.0 ... 39.0°Ra<br />
[0.5 ... 19.5 K]<br />
in steps of 1 °Ra [0.5 K]<br />
Factory setting: 8.0°Ra<br />
[4.0 K]<br />
Pump speed control<br />
DT S:<br />
Nominal temperature difference<br />
Adjustment range: 3.0 ... 60.0 °Ra<br />
[1.5 ... 30.0 K]<br />
in steps of 1 °Ra [0.5 K]<br />
Factory setting: 20.0 °Ra<br />
[10.0 K]<br />
RIS:<br />
Rise<br />
Adjustment range:<br />
2 ... 40 °Ra [1 ... 20 K]<br />
in steps of 2 °Ra [1 K]<br />
Factory setting: 4 °Ra [2 K]<br />
Minimum pump speed<br />
nMN:<br />
Pump speed control<br />
Adjustment range:<br />
30 ... 100<br />
in steps of 5 %<br />
Factory setting: 30<br />
| 20<br />
The controller works as a standard differential controller. If<br />
the switch-on difference is reached, the pump is activated.<br />
When the temperature difference falls below the adjusted<br />
switch-off temperature difference, the relay switches off.<br />
Note:<br />
The switch-on temperature difference must be<br />
at least 1 °Ra [0.5 K] higher than the switch-off<br />
tempe rature difference.<br />
Note:<br />
When the drainback option ODB is activated,<br />
the temperature differences DT O, DT F and<br />
DT S are set to a fixed adjustment:<br />
DT O = 20 °Ra [10 K]<br />
DT F = 8 °Ra [4 K]<br />
DT S = 30 °Ra [15 K]<br />
Previous adjustments made in these channels will<br />
be overridden and may have to be entered again if<br />
ODB is deactivated later on.<br />
Note:<br />
For pump speed control, the operation mode of<br />
relay 1 must be set to Auto (adjustment channel<br />
MAN1)<br />
When the switch-on temperature difference is reached,<br />
the pump is activated at full speed for 10 seconds. Then, the<br />
speed is reduced to the minimum pump speed value (factory<br />
setting = 30 %).<br />
If the temperature difference reaches the adjusted nominal<br />
temperature difference, the pump speed increases by one<br />
step (10 %). If the difference increases by the adjustable rise<br />
value, the pump speed increases by 10 % respectively until the<br />
maximum pump speed of 100 % is reached. The response of<br />
the controller can be adapted via the parameter “Rise”.<br />
Note:<br />
The nominal temperature difference must be<br />
at least 1 °Ra [0.5 K] higher than the switch-on<br />
tempe rature difference.<br />
A relative minimum pump speed can be allocated to the<br />
output R1 via the adjustment channel nMN.<br />
Note:<br />
When a load which is not speed-controlled is<br />
used, the value must be set to 100 % in order to<br />
deactivate pump speed control.<br />