<strong>SMA</strong> Solar Technology AG<br />

Safety<br />

2.3 Explanation of Symbols<br />

This section gives an explanation of all the symbols shown on the inverter and on the type label.<br />

2.3.1 Symbols on the Inverter<br />

Symbol<br />

Explanation<br />

Operation Display.<br />

Shows the operating status of the inverter.<br />

Ground fault or varistor defective.<br />

Read section 9.3 ”Red LED is Glowing Continuously” (page 52).<br />

Fault or disturbance.<br />

Read section 9 ”Troubleshooting” (page 46).<br />

Tap to switch on the display light and switch to the next message.<br />

2.3.2 Symbols on the Type Label<br />

DC circuit breaker Electronic Solar Switch (ESS)<br />

• If the Electronic Solar Switch connects, then the DC circuit is<br />

completed.<br />

• To interrupt the DC circuit and disconnect the inverter securely<br />

under load, you have to first pull out the Electronic Solar Switch<br />

and then remove all DC plug connectors , as described in section<br />

7.2 ”Opening the Inverter” (page 37).<br />

Symbol<br />

Explanation<br />

Beware of dangerous electrical voltage.<br />

The inverter operates at high voltages. <strong>All</strong> work on the inverter may be<br />

carried out by qualified personnel only.<br />

Beware of hot surface.<br />

The inverter can become hot during operation. Avoid contact during<br />

operation.<br />

Observe all documentation accompanying the inverter.<br />