<strong>SMA</strong> Solar Technology AG<br />
Troubleshooting<br />
Message<br />
VpvMax<br />
Watchdog<br />
Watchdog Srr<br />
Zac-Bfr<br />
Zac-Srr<br />
Description and corrective measure<br />
Overvoltage at DC input. The inverter may be damaged.<br />
Corrective measures<br />
Disconnect the inverter from the grid immediately.<br />
1. Turn off the line circuit breaker.<br />
2. Remove the Electronic Solar Switch.<br />
3. Disconnect all the DC plug connectors.<br />
4. Check DC voltage:<br />
– If the DC voltage is above the maximum input voltage, check the<br />
system design or contact the installer of the PV generator.<br />
– If the DC voltage is under the maximum input voltage, reconnect<br />
the inverter to the PV generator as described in section<br />
5.5 ”Connection of the PV Generator (DC)” (page 28).<br />
If the message occurs again, disconnect the inverter again and contact<br />
the <strong>SMA</strong> Serviceline (see section 13 ”Contact” (page 66)).<br />
Internal program run fault.<br />
Corrective measures<br />
• Contact the <strong>SMA</strong> Serviceline if this disturbance occurs frequently.<br />
The grid impedance is no longer within the permissible range ("Bfr" or<br />
"Srr" is an internal message of no relevance for the user). For safety<br />
reasons, the inverter disconnects itself from the grid. The impedance is<br />
calculated from both the grid impedance and the impedance of the AC<br />
cable of the inverter.<br />
Corrective measures<br />
• Check the grid impedance and grid connection on the inverter.<br />
• Use an AC cable with an adequate cross-sectional area<br />
(= low impedance) as described in section 5.3 ”Connection to the<br />
Public Grid (AC)” (page 22). If required, check and re-tighten the<br />
screws on the AC terminals.<br />
• If this fault recurs, please contact the <strong>SMA</strong> Serviceline.<br />
Installation Guide SB33_38-IEN100540 51