<strong>SMA</strong> Solar Technology AG<br />

Electrical Connection<br />

5. Thread the threaded sleeve (C) with sealing ring over the AC cable.<br />

6. Bend the AC cable. The bend radius must be at<br />

least four times the cable diameter.<br />

7. Shorten the cable.<br />

8. Shorten phase L and neutral conductor<br />

N 4 to 5 mm.<br />

9. Insert the PE protective conductor (green-yellow)<br />

into the screw terminal with the earth sign on the<br />

socket element and tighten the screw. The PE<br />

protective conductor must be longer than the<br />

connection wires of N and L.<br />

10. Insert the neutral conductor N (blue) in the screw<br />

terminal N on the socket element and tighten the<br />

screw.<br />

11. Insert phase L (brown or black) into the screw<br />

terminal L on the socket element and tighten the<br />

screw.<br />

12. Make sure the wires are securely connected.<br />

13. Push the threaded sleeve (C) onto the socket element (B) until it audibly snaps into place.<br />