Model 28624TN - Ready Remote
Model 28624TN - Ready Remote
Model 28624TN - Ready Remote
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Last Start Diagnostics:<br />
The system holds in memory the reason for the most recent<br />
remote start activation. This diagnostic report must be recalled<br />
using the following operation:<br />
1. Turn the ignition ON and then OFF in less than 5 seconds<br />
2. Within 5 seconds press and release the Monetary Switch<br />
3. After 2 seconds the LED will flash/pause and repeat 5<br />
times to indicate the cause of the most recent remote<br />
start activation.<br />
4. Count the LED flashes and consult the Last Start<br />
Diagnostic Chart<br />
Last Start Diagnostic Chart<br />
LED Description<br />
Flashes<br />
1 The <strong>Remote</strong> Starter has not been activated since the main power<br />
was connected<br />
2 The Transmitter was used to activate the <strong>Remote</strong> starter<br />
3 The Activation Input wire was used to activate the <strong>Remote</strong> starter<br />
4 Low temperature activated the <strong>Remote</strong> Starter in Vacation Mode<br />
5 Low battery voltage activated the <strong>Remote</strong> Starter in Vacation Mode<br />
6 No Diagnostics<br />
7 Daily Start activated the <strong>Remote</strong> Starter<br />
50 © 2006 Directed Electronics