APPENDIX A – SITE CONFIGURATION REQUIREMENTS<br />

To determine the site configuration, there are several factors that need careful attention.<br />

1 - Available Floor Space<br />

Each unit has a footprint of 12’ 8” (3.9 m) wide by 17’ 3”’ (5.26 m) deep, including the loading platform.<br />

Depending on the site topography, the actual configuration will vary.<br />

2 - Ceiling Clearances<br />

The ceiling height requirement is 12’ 10” (3.9 m) with a pathway of approximately 4’ (1.2 m) wide at the<br />

top, 2’ (0.61m) either side of center.<br />

3 - Floor Loading Capabilities<br />

Floors must be able to support the weight of the units. To obtain this information, consult an engineer or an<br />

architect.<br />

Approximate Unit Weight – 4200 lbs (1909 kg)<br />

Load Distribution per Square Foot – 25.26 lbs (11.4 kg)<br />

4 - Aisle Clearance<br />

Consult local building codes. A minimum of 6’ (1.83 m) is recommended, but should not supersede the<br />

local building codes.<br />

5 - Entrances & Exits<br />

Egress routs must be clear and unobstructed. Local building codes will dictate.<br />

6 - Environment<br />

Keep facility operating temperature reasonably stable. Temperatures less than 80 degrees Fahrenheit with<br />

humidity levels less than 60% would keep patrons comfortable and keep equipment functioning well. Also,<br />

for the best visual effect, facility lighting should be kept low.<br />

Warning – If the environment is not stable it will cause damage to the electronic<br />

equipment.<br />

7 - Floor Finishes<br />

A carpeted floor is the preferred floor finish. Tiled floors and bare concrete floors are okay but may require<br />

placing the machine on an anti-slip pad.<br />

8 - Truck Routes<br />

Depending on the size of the purchase, there could be a need to have access to the facility capable of<br />

accommodating large freight trucks, which require maneuvering room.<br />

9 - Docking<br />

Obtain and forward dock heights before shipping arrangements are made so that accommodations can be<br />

made for the ease of unloading.<br />

10 - Freight Elevators<br />

When installing units that are above the ground or dock level of your facility, examination of freight<br />

elevators for capacities, size and operability is necessary. Schedule time and operators for the day of<br />

delivery where applicable.