If the direction of movement is incorrect for any axis, reverse any two (2) phases as described in<br />

paragraph 3-3B above.<br />

2-5 Encoder wiring<br />

The encoders are wired so that the labeled terminals for A and A-not, B and B-not on the encoder are<br />

matched with corresponding terminals on the motion control interface board All cables return and start at<br />

the interface board.<br />

2-5A Encoder Positioning<br />

The pitch and roll encoders are mounted directly to the motor shaft from the rear of the motor so that the<br />

encoder is facing the motor from behind The lift encoder is mounted on the drive shaft connecting the<br />

motor to the ninety degree gear box. Located right inside rear of ride lower level.<br />

2-5B Encoder Behavior Confirmation<br />

For each axis, the encoder forms a closed loop with the motion control adapter to generate an analog signal<br />

that commands the drive motor to move in a specific direction. In the formula EP=DP-AP, (DP is the<br />

desired position, AP is the actual position and EP is the error position) a positive EP results in a positive<br />

analog signal to move the motor in the direction which will decrease the error.<br />

PITCH: As the unit moves clockwise (up) the encoder reading should return increasing<br />

values (positive). The clockwise Positive registry entry for the axis is set to 1 for true.<br />

ROLL: As the unit moves clockwise the encoder reading should return increasing values<br />

(positive). The clockwise Positive registry entry for the axis is set to 1 for true.<br />

LIFT: As the unit moves up, the encoder reading should return decreasing values to the<br />

registry, where in the software we reverse the appearance of the encoder reading using the<br />

Clockwise Positive registry entry for the axis (set to 0 for false) so that in the application we<br />

will see increasing values when the unit is going up in inches not degrees..<br />

If the value moves in the opposite direction, check the clockwise positive registry entry<br />

for that axis. If it is set correctly, check the encoder wiring.<br />

2-6 Mitsubishi Inverter Information<br />