Version 4.0<br />
• Added support for iQUBE 2 and removed<br />
support for iQUBE.<br />
NOTE: Version 4.0 requires Rev E CPU board or newer.<br />
Version 3.13<br />
• Added a new value to the Print<br />
Formatting section of the <strong>manual</strong> (see Section<br />
6.1, Table 6-1 on page 60).<br />
• Corrected comparisons to reduce the number<br />
of power-up calibrations counted by Audit<br />
Trail.<br />
• Added the speed-up of loading a user program<br />
by only erasing needed memory blocks.<br />
Version 3.10<br />
• Error Recovery - version 3.10.00 of the <strong>920i</strong><br />
now has a very sophisticated error recovery<br />
for the battery backed NVRAM. when a Save<br />
and Exit is performed after a Configuration<br />
and Calibration is performed, a copy of the<br />
NVRAM is stored in Flash for future<br />
recovery. If the <strong>920i</strong> is powered off at any<br />
time and the battery is not at peak<br />
performance, the NVRAM could come up<br />
with corrupted data. The next time the <strong>920i</strong> is<br />
powered up, the NVRAM is tested for a<br />
correct CRC checksum. If this is bad, there<br />
will be a special screen displayed showing the<br />
corrupt locations with directions to press<br />
ENTER to continue. The core will rewrite to<br />
NVRAM using the last copy of the last Save<br />
and Exit. At this time Date and Time are also<br />
checked. It will then open the Date/Time full<br />
screen edit function so the operator can check<br />
the current Date and Time. If correct, all that<br />
is needed is an ENTER key to continue. If<br />
incorrect, the operator can adjust the Date or<br />
Time and then push ENTER to continue. <br />
To ensure the latest copy of NVRAM is<br />
available for a power up, it is recommended<br />
that before powering down the <strong>920i</strong> for either<br />
overnight outage or temporary storage, the<br />
unit should be put into setup mode and a Save<br />
and Exit performed which will save a new<br />
copy of the NVRAM. On Legal-For-Trade<br />
units, if this cannot be performed, then the<br />
system will use the last Save and Exit and all<br />
databases and truck data should be uploaded<br />
to a PC prior to powering the <strong>920i</strong> down.<br />
• Removed the EXIT key during Setup mode.<br />
• Added a progress message during the clear of<br />
memory and loading a user program (see<br />
Section 5.6.1 on page 64)<br />
Version 3.09<br />
• The battery replacement procedure has been<br />
updated (see Section 2.9 on page 18).<br />
• A TOKENS parameter has been added to the<br />
SERIAL menu to allow changing the data<br />
stream tokens from the indicator front panel<br />
(see Section 3.2.2 on page 38).<br />
• Values for SWAP parameter on the FLDBUS<br />
menu have been changed to allow greater<br />
flexibility in byte-swapping for fieldbus cards<br />
(see Section 3.2.8 on page 56).<br />
• Improved database handling. Database access<br />
by multiple simultaneous requests is now<br />
controlled by allowing one read or write<br />
operation at a time, on a first-come,<br />
first-served basis.<br />
Version 3.08<br />
• A new value, KBDPRG, on the Port 2 serial<br />
menu allows keyboard scans to be passed<br />
directly to an iRite user program (see<br />
Figure 3-8 on page 38).<br />
• Support for negative tracking has been added<br />
to the ALGOUT menu (see Section 3.2.7 on<br />
page 55).<br />
• A new stream token, Z, has been added to the<br />
stream format status identifiers to<br />
indicate center-of-zero (see Table 11-8 on<br />
page 120).<br />
Version 3.07<br />
• Support has been added for the dual-channel<br />
analog output card (PN 103138) and the<br />
ControlNet interface card (PN 103136).<br />
• New OVRBASE parameter, on the<br />
REGULAT submenu of the FEATURE menu,<br />
allows specification of calibrated or scale zero<br />
as the base for overload calculation. See<br />
page 50 for more information.<br />
• A new top-level menu, FLDBUS, is now<br />
shown if a DeviceNet, Profibus, EtherNet/IP,<br />
or ControlNet is installed.The two parameters<br />
under the FLDBUS menu allow byte<br />
swapping to be enabled (SWAP parameter)<br />
and for the transfer size of the swapped bytes<br />
to be specified (DATASIZE). See<br />
Section 3.2.8 on page 56 for more<br />
information.<br />
• The default A/D sample rate (SMPRAT<br />
parameter on the SCALES menu) has been<br />
changed from 120 to 30 Hz.<br />
• The KEXIT command has been removed and<br />
replaced with KSAVEEXIT. (See<br />
Section Table 10-1. on page 96.)<br />
• Error codes returned on the XE serial<br />
command have been updated (see Table 11-3<br />
on page 116).<br />
Version 3.05-3.06<br />
• Support for local/remote indicator configurations<br />
provides function equivalent to a legal-for-trade<br />
Introduction 7