Version 4.0<br />

• Added support for iQUBE 2 and removed<br />

support for iQUBE.<br />

NOTE: Version 4.0 requires Rev E CPU board or newer.<br />

Version 3.13<br />

• Added a new value to the Print<br />

Formatting section of the <strong>manual</strong> (see Section<br />

6.1, Table 6-1 on page 60).<br />

• Corrected comparisons to reduce the number<br />

of power-up calibrations counted by Audit<br />

Trail.<br />

• Added the speed-up of loading a user program<br />

by only erasing needed memory blocks.<br />

Version 3.10<br />

• Error Recovery - version 3.10.00 of the <strong>920i</strong><br />

now has a very sophisticated error recovery<br />

for the battery backed NVRAM. when a Save<br />

and Exit is performed after a Configuration<br />

and Calibration is performed, a copy of the<br />

NVRAM is stored in Flash for future<br />

recovery. If the <strong>920i</strong> is powered off at any<br />

time and the battery is not at peak<br />

performance, the NVRAM could come up<br />

with corrupted data. The next time the <strong>920i</strong> is<br />

powered up, the NVRAM is tested for a<br />

correct CRC checksum. If this is bad, there<br />

will be a special screen displayed showing the<br />

corrupt locations with directions to press<br />

ENTER to continue. The core will rewrite to<br />

NVRAM using the last copy of the last Save<br />

and Exit. At this time Date and Time are also<br />

checked. It will then open the Date/Time full<br />

screen edit function so the operator can check<br />

the current Date and Time. If correct, all that<br />

is needed is an ENTER key to continue. If<br />

incorrect, the operator can adjust the Date or<br />

Time and then push ENTER to continue. <br />

To ensure the latest copy of NVRAM is<br />

available for a power up, it is recommended<br />

that before powering down the <strong>920i</strong> for either<br />

overnight outage or temporary storage, the<br />

unit should be put into setup mode and a Save<br />

and Exit performed which will save a new<br />

copy of the NVRAM. On Legal-For-Trade<br />

units, if this cannot be performed, then the<br />

system will use the last Save and Exit and all<br />

databases and truck data should be uploaded<br />

to a PC prior to powering the <strong>920i</strong> down.<br />

• Removed the EXIT key during Setup mode.<br />

• Added a progress message during the clear of<br />

memory and loading a user program (see<br />

Section 5.6.1 on page 64)<br />

Version 3.09<br />

• The battery replacement procedure has been<br />

updated (see Section 2.9 on page 18).<br />

• A TOKENS parameter has been added to the<br />

SERIAL menu to allow changing the data<br />

stream tokens from the indicator front panel<br />

(see Section 3.2.2 on page 38).<br />

• Values for SWAP parameter on the FLDBUS<br />

menu have been changed to allow greater<br />

flexibility in byte-swapping for fieldbus cards<br />

(see Section 3.2.8 on page 56).<br />

• Improved database handling. Database access<br />

by multiple simultaneous requests is now<br />

controlled by allowing one read or write<br />

operation at a time, on a first-come,<br />

first-served basis.<br />

Version 3.08<br />

• A new value, KBDPRG, on the Port 2 serial<br />

menu allows keyboard scans to be passed<br />

directly to an iRite user program (see<br />

Figure 3-8 on page 38).<br />

• Support for negative tracking has been added<br />

to the ALGOUT menu (see Section 3.2.7 on<br />

page 55).<br />

• A new stream token, Z, has been added to the<br />

stream format status identifiers to<br />

indicate center-of-zero (see Table 11-8 on<br />

page 120).<br />

Version 3.07<br />

• Support has been added for the dual-channel<br />

analog output card (PN 103138) and the<br />

ControlNet interface card (PN 103136).<br />

• New OVRBASE parameter, on the<br />

REGULAT submenu of the FEATURE menu,<br />

allows specification of calibrated or scale zero<br />

as the base for overload calculation. See<br />

page 50 for more information.<br />

• A new top-level menu, FLDBUS, is now<br />

shown if a DeviceNet, Profibus, EtherNet/IP,<br />

or ControlNet is installed.The two parameters<br />

under the FLDBUS menu allow byte<br />

swapping to be enabled (SWAP parameter)<br />

and for the transfer size of the swapped bytes<br />

to be specified (DATASIZE). See<br />

Section 3.2.8 on page 56 for more<br />

information.<br />

• The default A/D sample rate (SMPRAT<br />

parameter on the SCALES menu) has been<br />

changed from 120 to 30 Hz.<br />

• The KEXIT command has been removed and<br />

replaced with KSAVEEXIT. (See<br />

Section Table 10-1. on page 96.)<br />

• Error codes returned on the XE serial<br />

command have been updated (see Table 11-3<br />

on page 116).<br />

Version 3.05-3.06<br />

• Support for local/remote indicator configurations<br />

provides function equivalent to a legal-for-trade<br />

Introduction 7