17.01.2015 Views

920i Installation manual - Rice Lake Weighing Systems

920i Installation manual - Rice Lake Weighing Systems

920i Installation manual - Rice Lake Weighing Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

grounding clamps to determine cable lengths<br />

required to reach cable connectors. Mark<br />

cables to remove insulation and shield as<br />

described below:<br />

• For cables with foil shielding, strip insulation<br />

and foil from the cable half an inch (15 mm)<br />

past the grounding clamp (see Figure 2-2).<br />

Fold the foil shield back on the cable where<br />

the cable passes through the clamp. Ensure<br />

silver (conductive) side of foil is turned<br />

outward for contact with the grounding<br />

clamp.<br />

• For cables with braided shielding, strip cable<br />

insulation and braided shield from a point just<br />

past the grounding clamp. Strip another half<br />

inch (15 mm) of insulation only to expose the<br />

braid where the cable passes through the<br />

clamp (see Figure 2-2).<br />

2.3.3 Load Cells<br />

To attach cable from a load cell or junction box to an<br />

installed A/D card, route the cable through the cord<br />

grip and ground the shield wire as described in<br />

Section 2.3.2 on page 10.<br />

Next, remove connector J1 from the A/D card. The<br />

connector plugs into a header on the A/D card (see<br />

Figure 2-3). Wire the load cell cable from the load cell<br />

or junction box to connector J1 as shown in Table 2-1.<br />

Cord grip<br />

NOTE: Install lockwashers<br />

first, against enclosure,<br />

under grounding clamp<br />

Insulated cable<br />

Braid<br />

Cut insulation here<br />

for braided cables<br />

J1<br />

Foil (silver side out)<br />

Grounding clamp<br />

SIG+<br />

SIG–<br />

SEN+<br />

SEN–<br />

EXC+<br />

EXC–<br />

JP1 JP2<br />

Shield wire (cut)<br />

Cut insulation here<br />

for foil-shielded cables<br />

Figure 2-3. Single-Channel A/D Card<br />

Length of foil before folding<br />

back on cable insulation<br />

Figure 2-2. Grounding Clamp Attachment for Foil-Shielded<br />

and Braided Cabling<br />

• For load cell cables, cut the shield wire just<br />

past the grounding clamp. Shield wire<br />

function is provided by contact between the<br />

cable shield and the grounding clamp.<br />

• Route stripped cables through cord grips and<br />

clamps. Ensure shields contact grounding<br />

clamps as shown in Figure 2-2. Tighten<br />

grounding clamp nuts.<br />

• Finish installation using cable ties to secure<br />

cables inside of indicator enclosure.<br />

If using 6-wire load cell cable (with sense wires),<br />

remove jumpers JP1 and JP2 before reinstalling<br />

connector J1. For 4-wire installation, leave jumpers<br />

JP1 and JP2 on. For 6-wire load cell connections on<br />

dual-channel A/D cards, remove jumpers JP3 and JP4<br />

for connections to J2.<br />

When connections are complete, reinstall load cell<br />

connector on the A/D card and use two cable ties to<br />

secure the load cell cable to the inside of the<br />

enclosure.<br />

A/D Card<br />

Connector Pin<br />

Function<br />

1 +SIG<br />

2 –SIG<br />

3 +SENSE<br />

4 –SENSE<br />

5 +EXC<br />

6 –EXC<br />

• For 6-wire load cell connections to connector J1, remove<br />

jumpers JP1 and JP2.<br />

• For 6-wire load cell connections to connector J2 (dual A/D<br />

cards), remove jumpers JP3 and JP4.<br />

Table 2-1. A/D Card Pin Assignments<br />

<strong>Installation</strong> 11