condair cP3 D
condair cP3 D
condair cP3 D
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
31<br />
5.6 Electric installation<br />
5.6.1 Wiring diagram Condair CP3 D<br />
A1<br />
DRIVER BOARD<br />
F2<br />
200mAF<br />
J2<br />
LINK UP<br />
X2 X7 X4 X3<br />
SWITCH VTX SUPPLY INLET V. DRAIN V. CONTACTOR<br />
LinkUp<br />
J4 Termination<br />
EXTERNAL CON.<br />
J1<br />
CPU BOARD<br />
JP3<br />
CONT.SIGN<br />
V+ INGND<br />
OUT 5V<br />
OUT 24V<br />
LIM. SIGN<br />
INGND<br />
JP1<br />
BLOWER<br />
V+ IN<br />
X6<br />
Modul B<br />
P N P1<br />
LEV. SENSOR<br />
X5<br />
F1 6.3 AT<br />
X1<br />
MAIN SUPPLY<br />
PE L1 N SC1 SC2<br />
SW1<br />
H1<br />
CPU BOARD<br />
CP3 Card<br />
Main unit<br />
J3<br />
DRIVER B<br />
J2<br />
FAULT REMOTE<br />
J<br />
+ –<br />
Heating<br />
J1 DRIVER A J4<br />
U1<br />
K1<br />
L1 L2 L3<br />
SW2<br />
X0<br />
H2<br />
STEAM BATH<br />
BOARD<br />
L1 L2 L3<br />
M2<br />
X2 X3 X4<br />
5 4 3 2 1 4 3 2 1 4 3 2 1<br />
AC LAMP FAN GND LIGHT ON 24V TEMP TEMP<br />
SW3<br />
S2<br />
Q3<br />
S1<br />
SENSOR<br />
SWITCH<br />
24V<br />
M1<br />
40 °C<br />
AIN<br />
U2<br />
F3<br />
L1 L2 L3 PE<br />
400 V/3~/50..60 Hz<br />
230 V/3~/50..60 Hz<br />
Q3<br />
F3<br />
AIN<br />
M3<br />
24V 0V<br />
H3<br />
L1 N PE<br />
230 V/1~/50..60 Hz<br />
Q4<br />
F4<br />
L1 N PE<br />
230 V/1N~/50..60 Hz<br />
S1 Temperature sensor (KTY)<br />
S2 Max. temperature switch 72 °C<br />
SW1 On/Off switch steam bath<br />
SW2 On/Off switch lightning steam bath<br />
SW3 Door switch steam bath (option)<br />
U1 Analogue output temperature 0-10V (=0-100°C)<br />
U2 Analogue output temperature signal for the control of the flap actuator M3<br />
X0 Connection terminal heating voltage<br />
X1 Connection terminal control voltage<br />
3<br />
2<br />
1<br />
SC1 SC2 N L1 N L1 PE PE N PUMP<br />
1 2 3 4 5 6 7 1 2 3<br />
X1 X5<br />
TEMP<br />
SWITCH<br />
F1 4AT F2 4AT<br />
FAN LAMP<br />
J2<br />
24V<br />
18V<br />
15V<br />
0V<br />
4 3 2 1<br />
GND<br />
24V<br />
PUMP<br />
REL2 REL1 LAMP<br />
J3 J1<br />
0V<br />
15V<br />
18V<br />
24V<br />
rt bl rs gu<br />
N<br />
L1<br />
Fault Remote Board<br />
H<br />
Analog Out<br />
4<br />
F1<br />
100mA<br />
3<br />
2<br />
1<br />
2<br />
1<br />
Steam Unit ON<br />
Service<br />
Error<br />
Sensor Supply<br />
Max. 60mA<br />
1 2 3 4 5 6 7 8 9 10<br />
H2 Control lamp lightning steam bath On/Off<br />
H3 Lightning steam bath (24VAC, max. 2x 25W)<br />
J Short circuited, if no door switch is connected<br />
K1 Main contactor (for connecting the heating voltage supply to the unit)<br />
M1 Fragrance pump (1x230VAC)<br />
M2 Fan steam bath cabin (24VAC, max. 50W)<br />
M3 Flap actuator (alternatively to the fan)<br />
Q3 External service switch heating voltage supply<br />
Q4 External service switch control voltage supply<br />
A1 Temperature sensor (0-10V)<br />
F1 Internal fuse “Driver board” (6.3 A, slow acting)<br />
F2 Internal fuse “Driver board” control signal (200 mA, fast acting)<br />
F1 Fuse fan “Steam bath board” (4 A, slow acting)<br />
F2 Fuse lightning “Steam bath board” (4 A, slow acting)<br />
F3 External fuse heating voltage supply<br />
F4 External fuse control voltage supply<br />
H Remote operating and fault indication<br />
H1 Control lamp steam bath On/Off