41<br />

Description of the control mode settings<br />

– Manual: The steam generator must be switched on and off via the Start/Stop key<br />

in the operating display.<br />

CP3 D45 400V3<br />

Steam Bath :Standby<br />

Temperature :34°C<br />

Setpoint :48°C<br />

05.05.2008 12.00.00<br />

Start Light<br />

Menu<br />

CP3 D45 400V3<br />

Steam Bath :Heating<br />

Temperature :37°C<br />

Setpoint :48°C<br />

05.05.2008 12.05.00<br />

Stop Light<br />

Menu<br />

– Timer: The steam generator is switched on and off time controlled via the day<br />

timer. The timer settings can be accessed by pressing the key in<br />

the operating display.<br />

CP3 D45 400V3<br />

Steam Bath :Standby<br />

Temperature :34°C<br />

Setpoint :48°C<br />

05.05.2008 12.00.00<br />

Timer<br />

Light<br />

Menu<br />

Timer<br />

Status :Off<br />

Start time :18:00<br />

Duration :15min<br />

Esc<br />

Set<br />

– Status: activate (On) or deactivate (Off) timer function<br />

– Start time: set starting time (format: hh:mm)<br />

– Duration: Set heating time in minutes<br />

6.6.3 Setting the fragrance pump settings<br />

Aroma<br />

Pump<br />

:On<br />

Interval :5min<br />

Impulse :3s<br />

Esc<br />

Set<br />

Select “Aroma” in the main menu, then press the key. The<br />

fragrance pump settings appear. Press the < > and < > keys in order<br />

to select the individual settings and press the key to call up the<br />

modification dialogue for the selected setting.<br />

Description of the fragrance pump settings<br />

– Pump: Activating and deactivating the fragrance pump.<br />

Factory setting: On<br />

Options:<br />

On (Pump activated)<br />

Off (Pump deactivated)<br />

– Interval: Setting the interval time in minutes for the pump impulses.<br />

Factory setting: 5 min<br />

Setting range: 2 ... 20 min<br />

– Impulse: Setting the duration for a pump impulse in seconds.<br />

Factory setting: 3 s<br />

Setting range: 2 ... 10 s