43<br />
– Wochen Timer: With the settings in the submenu “Week Timer” you can configure the<br />
week timer for the time controlled operation of the steam generator.<br />
Note: This menu item is available only if the operating mode (see previous<br />
menu item “Operation”) is set to “WeekTime”.<br />
– Week timer deactivated:<br />
Week Timer<br />
Timer :Off<br />
Event 1 :18:00<br />
Event 2 :19:00<br />
Event 3 :--:--<br />
Event 4 :--:--<br />
Esc<br />
Set<br />
– Week timer activated:<br />
Week Timer<br />
Timer :On<br />
Event 1 :18:00<br />
Event 2 :19:00<br />
Event 3 :--:--<br />
Event 4 :--:--<br />
Esc<br />
Set<br />
Event 1<br />
Weekday :Mo-Fr<br />
Time :18:00<br />
Steam Bath :On<br />
Esc<br />
Set<br />
If the timer is activated, up to eight switching<br />
points (events 1 - 8) can be defined to switch<br />
the steam generator On or Off.<br />
Each switching point is defined by a weekday<br />
or weekday range, the switching point and<br />
the desired operating status of the steam<br />
generator.<br />
Configuration notes:<br />
– the settings of an event remain active up to the next event.<br />
– the software does not check the plausibility of the timer settings.<br />
Therefore, make sure your settings make sense.<br />
– Fan: With the settings in the submenu “Fan” you can determine the operating<br />
mode of the fan as well as the post-operational time of the fan for drying<br />
the steam bath cabin.<br />
Fan<br />
Mode<br />
:3 Stages<br />
Drying Time :20min<br />
Esc<br />
Set<br />
– Mode: Setting the operating mode of the fan.<br />
Factory setting:<br />
Options:<br />
3 Stages<br />
3 Stages (Operation of the fan with three<br />
performance levels 15/18/24VAC, which are<br />
controlled in dependency of the temperature<br />
in the steam bath cabin)<br />
1 Stage (Operation of the fan with only one<br />
performance level 24VAC)<br />
Off (Fan off)<br />
– Drying time: Setting the post-operational time of the fan for<br />
drying the steam bath cabin.<br />
Factory setting:<br />
Setting range:<br />
20 min<br />
1 ... 60 min