43<br />

– Wochen Timer: With the settings in the submenu “Week Timer” you can configure the<br />

week timer for the time controlled operation of the steam generator.<br />

Note: This menu item is available only if the operating mode (see previous<br />

menu item “Operation”) is set to “WeekTime”.<br />

– Week timer deactivated:<br />

Week Timer<br />

Timer :Off<br />

Event 1 :18:00<br />

Event 2 :19:00<br />

Event 3 :--:--<br />

Event 4 :--:--<br />

Esc<br />

Set<br />

– Week timer activated:<br />

Week Timer<br />

Timer :On<br />

Event 1 :18:00<br />

Event 2 :19:00<br />

Event 3 :--:--<br />

Event 4 :--:--<br />

Esc<br />

Set<br />

Event 1<br />

Weekday :Mo-Fr<br />

Time :18:00<br />

Steam Bath :On<br />

Esc<br />

Set<br />

If the timer is activated, up to eight switching<br />

points (events 1 - 8) can be defined to switch<br />

the steam generator On or Off.<br />

Each switching point is defined by a weekday<br />

or weekday range, the switching point and<br />

the desired operating status of the steam<br />

generator.<br />

Configuration notes:<br />

– the settings of an event remain active up to the next event.<br />

– the software does not check the plausibility of the timer settings.<br />

Therefore, make sure your settings make sense.<br />

– Fan: With the settings in the submenu “Fan” you can determine the operating<br />

mode of the fan as well as the post-operational time of the fan for drying<br />

the steam bath cabin.<br />

Fan<br />

Mode<br />

:3 Stages<br />

Drying Time :20min<br />

Esc<br />

Set<br />

– Mode: Setting the operating mode of the fan.<br />

Factory setting:<br />

Options:<br />

3 Stages<br />

3 Stages (Operation of the fan with three<br />

performance levels 15/18/24VAC, which are<br />

controlled in dependency of the temperature<br />

in the steam bath cabin)<br />

1 Stage (Operation of the fan with only one<br />

performance level 24VAC)<br />

Off (Fan off)<br />

– Drying time: Setting the post-operational time of the fan for<br />

drying the steam bath cabin.<br />

Factory setting:<br />

Setting range:<br />

20 min<br />

1 ... 60 min