Operation MDE 40<br />

5.4 Trouble-shooting<br />

Always disconnect the mains plug of the small compact<br />

dryer and the drying bin heater from the power supply<br />

before carrying out any fault rectifications.<br />

Secure EMERGENCY-OFF switch at the small compact dryer<br />

against unauthorised reconnection.<br />

Faults may only be rectified by authorised, trained and<br />

properly instructed specialists.<br />

At malfunction, the alarm display (3, Fig. 5-3) on the operating panel lights up.<br />

The faults listed are examples only, and are not to be regarded as exhaustive.<br />

Fault Cause Rectification<br />

lluminated "ON-OFF" <strong>Small</strong> compact dryer is not plugged in<br />

Plug in small compact dryer<br />

switch (2, Fig. 5-3)<br />

does not light up EMERGENCY-OFF switch not activated Activate EMERGENCY-OFF<br />

switch<br />

Illuminated switch (2, Fig. 5-3) is not switched on Switch on illuminated switch<br />

Power supply failure<br />

Check power supply<br />

Lamp defective<br />

Change lamp<br />

Fuse 12 F1 (9, Fig. 7-1) defective<br />

Change fuse 12 F1<br />

Blower is not Fuse 11 F3 (8, Fig. 7-1) defective Change fuse 11 F3<br />

operating Blower defective Change blower<br />

Alarm display Air pressure monitor (11, Fig. 7-2) defective Change<br />

(3, Fig. 5-3) lights up Blower is not operating Change fuse 11 F3<br />

Hose loose or leaking<br />

Check, change if necessary<br />

Air flow too weak<br />

Check hoses and connection<br />

for leaks<br />

Temperature limit switch for desiccant cartridge 1 Reset 6.3.1<br />

has switched off<br />

Temperature limit switch for desiccant cartridge 2 Reset 6.3.1<br />

has switched off<br />

Temperature limit switch defective<br />

Change<br />

Sensor or capillary tube of the temperature limit Change<br />

switch defective<br />

Wrong position of valve flap Adjust valve flap 6.3.6<br />

Temperature at<br />

drying bin does not<br />

reach set temperature<br />

Air flow too weak<br />

Differential pressure monitor (5, Fig. 7-3)<br />

defective<br />

Check hoses and<br />

connections for leaks<br />

Check 6.3.5<br />

change if necessary<br />

Safety thermostat has tripped Reset 6.3.4<br />

Heater defective<br />

Measure resistance,<br />

change if necessary<br />

5.4