Maintenance and repair MDE 40<br />

6.3.2 Changing the temperature sensor at the drying bin<br />

NOTE<br />

The temperature sensor (1, Fig. 6-7) must<br />

be fitted in a way that the slot lies in<br />

parallel to the air flow direction<br />

Fig. 6-7.<br />

1<br />

Air flow<br />

direction<br />

Fig. 6-7<br />

Fitting position of the<br />

temperature sensor<br />

6.3.3 Checking the air pressure monitor<br />

Remove hose (2, Fig. 6-8) at the pressure<br />

monitor (1)<br />

Air pressure monitor alright if<br />

<br />

<br />

alarm display lights up<br />

regeneration air heater switches off<br />

(in case the regeneration air heater is<br />

switched on)<br />

1<br />

2<br />

Fig. 6-8<br />

Checking the air pressure monitor<br />