Option MDE 40<br />
A<br />
After cooler<br />
The after cooler is required for drying with very<br />
high temperatures (approx. > 120 °C).<br />
The cooler the return air temperature, the better<br />
the air absorption of the return air, i.e. efficiency<br />
of the drying system increases.<br />
The return air from the drying bins passes<br />
through the heat exchanger (1, Fig. A-1).<br />
1<br />
2<br />
The heat exchanger is cooled by the cooling air<br />
of the filter fan (2) during the entire time of<br />
operation.<br />
Fig. A-1<br />
After cooler<br />
Maintenance<br />
Clean the after cooler every three months.<br />
In case very dusty material is dried, clean the after cooler more often.<br />
Spare parts<br />
Spare parts<br />
Item No. off Designation Part no.<br />
- 1 After cooler, complete 501 459<br />
1 1 Heat exchanger 407 573<br />
2 1 Filter fan 403 652<br />
A.1