11 Option<br />

Implosion filter option METRO 0.5 to 1.5<br />

11.1.3 Maintenance<br />

Fig. 11.2 – Implosion filter<br />

[1] Nut<br />

[2] Sealing ring<br />

[3] Cover plate of implosion filter<br />

[4] Implosion filter<br />

[5] Spacer<br />

[6] Seal<br />

[7] Cable passage<br />

[8] Plug connector<br />

Removing implosion filter<br />

Prepare the hopper <strong>loader</strong> for maintenance (see "Before starting work" on Page 32).<br />

Label the PU tubes to the implosion filter and undo the PU tubes.<br />

Remove the plug connector [8].<br />

Slacken the nut [1] and remove the sealing ring [2].<br />

Remove the cover plate of the implosion filter [3] and pull the implosion filter [4] off.<br />

Remove the spacer [5] and the seal [6].<br />

Installing implosion filter<br />

Assemble in reverse order.<br />

Make sure that the PU tubes are correctly installed.<br />