sample preparation - Harvard Apparatus UK
sample preparation - Harvard Apparatus UK
sample preparation - Harvard Apparatus UK
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>sample</strong> <strong>preparation</strong><br />
Fast Micro-Equilibrium DIALYZERS & Membranes<br />
Ordering Information<br />
Fast Micro-Equilibrium DIALYZERS & Membranes<br />
Chamber Volume: 25 µl 50 µl 100 µl 250 µl 500 µl 1000 µl 1500 µl<br />
Fast Micro-Equilibrium DIALYZERS<br />
Qty. of 1 SP1 7416-251D SP1 7416-501D SP1 7416-1001D SP1 7416-2501D SP1 7416-5001D SP1 7416-10001D SP1 7416-15001D<br />
Qty. of 5 SP1 7416-255D SP1 7416-505D SP1 7416-1005D SP1 7416-2505D SP1 7416-5005D SP1 7416-10005D SP1 7416-15005D<br />
Additional (Link) Chambers<br />
Qty. of 1 SP1 7416-251L SP1 7416-501L SP1 7416-1001L SP1 7416-2501L SP1 7416-5001L SP1 7416-10001L SP1 7416-15001L<br />
Qty. of 5 SP1 7416-255L SP1 7416-505L SP1 7416-1005L SP1 7416-2505L SP1 7416-5005L SP1 7416-10005L SP1 7416-15005L<br />
Membranes: Pack of 25<br />
for Chamber Volume: 25ul, 50µl or 100ul 250ul, 500ul, 1000 or 1500ul<br />
A. Regenerated Cellulose MEMBRANES:<br />
1k Da MWCO SP1 7416-RC1K SP1 7415-RC1K<br />
2k Da MWCO SP1 7416-RC2K SP1 7415-RC2K<br />
5k Da MWCO SP1 7416-RC5K SP1 7415-RC5K<br />
10k Da MWCO SP1 7416-RC10K SP1 7415-RC10K<br />
25k Da MWCO SP1 7416-RC25K SP1 7415-RC25K<br />
50k Da MWCO SP1 7416-RC50K SP1 7415-RC50K<br />
B. Cellulose Acetate MEMBRANES:<br />
100 Da MWCO SP1 7416-CA100 SP1 7415-CA100<br />
500 Da MWCO SP1 7416-CA500 SP1 7415-CA500<br />
1k Da MWCO SP1 7416-CA1K SP1 7415-CA1K<br />
2k Da MWCO SP1 7416-CA2K SP1 7415-CA2K<br />
5k Da MWCO SP1 7416-CA5K SP1 7415-CA5K<br />
10k Da MWCO SP1 7416-CA10K SP1 7415-CA10K<br />
25k Da MWCO SP1 7416-CA25K SP1 7415-CA25K<br />
50k Da MWCO SP1 7416-CA50K SP1 7415-CA50K<br />
100k Da MWCO SP1 7416-CA100K SP1 7415-CA100K<br />
300k Da MWCO SP1 7416-CA300K SP1 7415-CA300K<br />
C. Polycarbonate MEMBRANES:<br />
0.01 um Pore Size SP1 7416-PC01 SP1 7415-PC01<br />
0.05 um Pore Size SP1 7416-PC05 SP1 7415-PC05<br />
0.10 um Pore Size SP1 7416-PC10 SP1 7415-PC10<br />
0.60 um Pore Size SP1 7416-PC60 SP1 7415-PC60<br />
Membranes are supplied either as dry or in 0.05% sodium azide solution. They are ready to use<br />
after rinsing with deionized water and buffer.<br />
Regenerated Cellulose membranes are more stable in organic solvents, but the MWCO range is<br />
not as sharply defined as that of Cellulose Acetate membranes.<br />
Cellulose Acetate membranes have a sharp MWCO range. They are intended only for aqueous<br />
solutions, and the presence of an organic solvent is not recommended.<br />
Polycarbonate membranes are more stable in organic solvents. They are available in four highly<br />
controlled pore sizes for a well defined MWCO range.<br />
www.harvardapparatus.com phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 51