21.01.2015 Views

sample preparation - Harvard Apparatus UK

sample preparation - Harvard Apparatus UK

sample preparation - Harvard Apparatus UK

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>sample</strong> <strong>preparation</strong><br />

96-Well DispoEquilibrium DIALYZER <br />

Samples from 50 µl to 300 µl (Single use)<br />

• Patented<br />

• 96-well format<br />

• Individual membrane for each well<br />

• Small <strong>sample</strong> volumes: 50 µl to 200 µl<br />

• Ultra-thin regenerated<br />

cellulose membranes<br />

• Membranes are free of sulfur<br />

and heavy metal contamination<br />

• High well-to-well reproducibility<br />

• Excellent <strong>sample</strong> recovery (>95%)<br />

96-Well Equilibrium DIALYZER Plate<br />

SP1 74-2330 & SP1 74-2331<br />

U.S. Patent 6,458,275<br />

Dual Plate Rotator SP1 74-2334<br />

8-Plate Rotator Oven<br />

SP1 74-2335<br />

Plate Rotator<br />

SP1 74-2302<br />

• Protein and Protein-drug<br />

binding assays<br />

• Receptor binding assays<br />

• Ligand binding assays<br />

• Protein-protein and Protein-<br />

DNA interactions<br />

The single use, 96-Well Equilibrium DIALYZER is a unique patented product for the<br />

simultaneous assay of 96 <strong>sample</strong>s. Each well in this system has a separate<br />

membrane and thus eliminates the possibility of <strong>sample</strong> cross-contamination.<br />

Reproducibility is very high across the different wells of the Equilibrium DIALYZER<br />

and <strong>sample</strong> recovery is excellent. The 96-Wells are sealed with 8-cap strips or a<br />

single-well, pierceable, self-sealing plate seal mat. Thus some wells or all 96 wells<br />

can be used with <strong>sample</strong>s or capped unused wells for future experiments. The<br />

96-Well Equilibrium DIALYZER utilizes high-quality regenerated cellulose membranes<br />

available with MWCO’s of 5,000 or 10,000 Daltons. Rotator is required. Includes<br />

twenty four 8-cap strips. Single plate seal mat is available.<br />

Single and Dual Plate Rotators<br />

A Single or Dual Plate Rotator with variable rotation rates is available for use with<br />

the <strong>Harvard</strong> <strong>Apparatus</strong> 96-Well Equilibrium DIALYZER. The Rotator speeds up the<br />

equilibrium dialysis process by keeping the <strong>sample</strong> in constant motion thereby<br />

ensuring higher reproducibility of results.<br />

8-Plate Rotator Incubator<br />

The 8-Plate Rotator Incubator is used for temperature controlled studies in the<br />

96-Well Equilibrium DIALYZER. The Rotator Incubator consists of an oven and a<br />

special carousel to hold up to 8 plates simultaneously.<br />

Order # Product Price $<br />

SP1 74-2330 96-Well Equilibrium Dialysis Plate, Membrane MWCO 5,000 Daltons, pkg. of 1<br />

SP1 74-2331 96-Well Equilibrium Dialysis Plate, Membrane MWCO 10,000 Daltons, pkg. of 1<br />

SP1 74-2323 8-Cap Strips, pkg. of 12 17.00<br />

SP1 74-2322 Plate Seal Mat with Individual Well Inserts, Pierceable and Self-Sealable, pkg. of 2<br />

SP1 74-2302 Single Plate Rotator, pkg. of 1 510.00<br />

SP1 74-2334 Dual Plate Rotator, pkg. of 1 725.00<br />

SP1 74-2335 8 Plate Rotator Incubator, 110 V, pkg. of 1 3,050.00<br />

SP1 74-2336 8 Plate Rotator Incubator, 220 V, pkg. of 1 3,050.00<br />

SP1 74-2337 Carousel, Only for 8-Plate Rotator 460.00<br />

54 www.harvardapparatus.com phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732