29.01.2015 Views

dectron_design - RJI-Sales.com

dectron_design - RJI-Sales.com

dectron_design - RJI-Sales.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Heat Rejection Data<br />

Natatorium<br />

Water-Cooled Data<br />

Rejecting excess recovered heat can be done by adding<br />

another water-cooled condenser to the DRY-O-TRON® ;<br />

referred to as Dectron Inc.’s water-cooled air conditioning<br />

option. This condenser can be piped to a cooling tower,<br />

chilled water loop or heat pump loop…wherever cooling<br />

water is available. The DRY-O-TRON® is equipped with all<br />

the necessary hardware (condenser, receiver, head-pressure<br />

control valves, etc.) and programming. There are no water<br />

regulating valves used in these constant water flow applications.<br />

The advantage of the water-cooled option is that it is a<br />

packaged solution (no field refrigerant piping) with the<br />

lowest system charge.<br />

DS/RS/DB/RB/DA5/RA5 Water Condenser Selection Table<br />

Closed Loops<br />

Heat<br />

Water-Cooled A/C Dry Cooler A/C<br />

Unit<br />

Water-Cooled A/C<br />

Rejection Plate Type HX Plate Type HX<br />

Size<br />

(Btu/h) GPM Conn. Type GPM Conn. GPM Conn.<br />

010 37,900 6.0 3/4 MPT Coaxial N/A N/A 8 1 MPT<br />

015 45,200 6.0 3/4 MPT Coaxial N/A N/A 10 1 MPT<br />

020 66,400 8.5 1 MPT Coaxial 8.0 1 MPT 14 1 MPT<br />

030 90,700 15.0 1 1/4 MPT Coaxial 10.0 1 1/4 MPT 20 1 1/4 MPT<br />

040 125,200 20.0 1 1/4 MPT Coaxial 15.0 1 1/4 MPT 28 1 1/2 MPT<br />

042 132,700 17.0 1 1/4 MPT Coaxial 16.0 1 1/4 MPT 28 1 1/2 MPT<br />

050 166,000 20.0 1 1/4 MPT Coaxial 20.0 1 1/4 MPT 36 1 1/2 MPT<br />

060 205,200 30.0 1 1/2 MPT Coaxial 20.0 1 1/4 MPT 45 2 MPT<br />

062 181,400 30.0 1 1/2 MPT Coaxial 20.0 1 1/4 MPT 40 2 MPT<br />

080 246,200 40.0 1 1/2 MPT Coaxial 30.0 1 1/2 MPT 54 2 MPT<br />

100 334,000 40.0 1 1/2 MPT Coaxial 40.0 1 1/2 MPT 73 2 1/2 MPT<br />

102 332,000 40.0 1 1/2 MPT Coaxial 40.0 1 1/2 MPT 73 2 1/2 MPT<br />

120 432,600 60.0 2 MPT Coaxial 50.0 2 MPT 94 2 1/2 MPT<br />

122 410,400 60.0 2 MPT Coaxial 50.0 2 MPT 94 2 1/2 MPT<br />

150 483,100 60.0 2 MPT Coaxial 60.0 2 MPT 107 3 1/8 O.D.<br />

152 492,400 80.0 2 MPT Coaxial 60.0 2 MPT 107 3 1/8 O.D.<br />

162 584,700 80.0 2 MPT Coaxial 70.0 2 MPT 127 3 1/8 O.D.<br />

182 668,000 80.0 2 MPT Coaxial 80.0 2 MPT 145 3 1/8 O.D.<br />

202 734,800 100.0 2 1/2 MPT Shell+Tube 90.0 2 1/2 MPT 160 3 1/8 O.D.<br />

242 817,100 120.0 2 1/2 MPT Shell+Tube 100.0 2 1/2 MPT 178 4 1/8 O.D.<br />

282 966,200 140.0 3 1/8 O.D. Shell+Tube 120.0 3 1/8 O.D. 210 4 1/8 O.D.<br />

362 1,270,100 140.0 3 1/8 O.D. Shell+Tube 160.0 3 1/8 O.D. 276 4 1/8 O.D.<br />

482 1,726,400 240.0 4 1/8 O.D. Shell+Tube 200.0 4 1/8 O.D. 375 5 1/8 O.D.<br />

562 2,010,300 280.0 4 1/8 O.D. Shell+Tube 240.0 4 1/8 O.D. 437 5 1/8 O.D.<br />

Maximum water-cooled condenser pressure drop = 10 psi<br />

The above GPM are based on 90°F EWT (except dry cooler, which is based on 110°F EFT). With a lower EWT, a lower<br />

water flow rate will be sufficient :<br />

EWT 90°F - 85°F 80°F 75°F 70°F 65°F 60°F 55°F<br />

% of GPM 100 86 80 74 69 65 61<br />

Where water temperatures will exceed 90°F EWT, larger condensers will be required. Please contact factory.<br />

On sizes 010 to 080, the water circuit can be <strong>design</strong>ed for water-saving applications. The DRY-O-TRON® is<br />

equipped with an on/off motorized water valve and a water-regulating valve.<br />