Troubleshooting Windows Deployments 2012-09-11 - TechNet Blogs
Troubleshooting Windows Deployments 2012-09-11 - TechNet Blogs
Troubleshooting Windows Deployments 2012-09-11 - TechNet Blogs
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
10804 ZTIExecuteRunbook.ws<br />
f<br />
10805 ZTIExecuteRunbook.ws<br />
f<br />
10806 ZTIExecuteRunbook.ws<br />
f<br />
Unable to get Orchestrator job runbook<br />
instance.<br />
Unable to get Orchestrator job runbook<br />
instance parameters.<br />
Runbook did not complete successfully,<br />
final status = <br />
9002 ZTIOSRole.wsf Unable to located the selected set of<br />
roles in ServerManager.xml<br />
(OSRoleIndex = )<br />
9003 ZTIOSRole.wsf Unknown OS current version value,<br />
unable to install roles.<br />
(OSCurrentVersion =<br />
%OSCurrentVersion%)<br />
9601 ZTITatoo.wsf ERROR - ZTITatoo state restore task<br />
should be running in the full OS,<br />
aborting.<br />
the specified runbook. Without this, MDT is<br />
unable to determine when the runbook execution<br />
has completed.<br />
3 8 The ZTIExecuteRunbook script was not able to<br />
retrieve the Orchestrator job runbook instance via<br />
the Orchestrator web service. Without this, MDT<br />
is unable to get the results from the job.<br />
3 8 The ZTIExecuteRunbook script was not able to<br />
retrieve the Orchestrator job runbook instance via<br />
the Orchestrator web service. Without this, MDT<br />
is unable to set task sequence variables with the<br />
parameters returned by the job.<br />
7 9 Orchestrator reported that the runbook job failed.<br />
To determine the cause, check on the Orchestrator<br />
server to see what happened.<br />
1 7 The operating system selected in the “Install Roles<br />
and Features” couldn’t be found in the<br />
ServerManager.xml file. That should never<br />
happen.<br />
5 9 In order for the “Install Roles and Features” step to<br />
know what operating system it is working with, it<br />
looks at the OSCurrentVersion task sequence<br />
variable. If this variable isn’t set (maybe because<br />
you aren’t using an MDT task sequence and didn’t<br />
precede this step with the required “Use Toolkit<br />
Package” and “Gather” steps), or if it is set to<br />
something invalid (e.g. “WinPE” if you are<br />
incorrectly running this step in <strong>Windows</strong> PE) you’ll<br />
get this error.<br />
3 9 The ZTITatoo script found that it was running in<br />
<strong>Windows</strong> PE, when it expected to be running in the<br />
new operating system. This might happen if the<br />
boot order on the system was wrong and the<br />
computer accidentally booted back into <strong>Windows</strong><br />
PE.<br />
Page | 17