4.1.2 Modelling of the damper<br />

The damping coefficients have a displacement dependency according to the experiments. These<br />

dynamic characteristics of the damper are introduced into a four parameter model as shown in<br />

Fig 12,<br />

Fig. 11 Isolation <strong>spring</strong> element Fig. 12 4 parameter model Table 2 Parameters of the 4 parameter model<br />

where the damping coefficients <strong>and</strong> the damper stiffnesses are taken into account according to the<br />

experiments for every frequency. According to Fig. 9 the damping coefficients were reduced to<br />

87 % in the horizontal direction <strong>and</strong> to 60 % in the vertical direction. The parameters of the<br />

4 parameter model are shown in Table 2.<br />

4.2 The procedure of the response analysis<br />

With the help of a three dimensional frequency response analysis program <strong>and</strong> a three<br />

dimensional time history response analysis program the response analysis was done as follows.<br />

(1) The <strong>spring</strong> rates of the <strong>spring</strong> unit were assumed to be linear. In this way the three dimensional<br />

frequency response analysis program was run. Next, the three dimensional time history response<br />

analysis program was run. Then the similarity of the two wave forms gained from the two analysis<br />

was compared.<br />

(2) The <strong>spring</strong> was modeled as a combination of a vertical <strong>spring</strong> element <strong>and</strong> a multi <strong>spring</strong><br />

element for the horizontal shear direction. The damper was modeled as a four parameter model as<br />

shown in Fig. 12. Then the three dimensional frequency response analysis program was run.<br />

4.3 Earthquake records used<br />

Earthquake records used in this analysis were modified from those of El Centro, Taft <strong>and</strong><br />

Hachinohe Earthquakes. The strength levels of the earthquake records were 50 kine for the<br />

horizontal NS <strong>and</strong> EW direction vectors.