4.1.2 Modelling of the damper<br />
The damping coefficients have a displacement dependency according to the experiments. These<br />
dynamic characteristics of the damper are introduced into a four parameter model as shown in<br />
Fig 12,<br />
Fig. 11 Isolation <strong>spring</strong> element Fig. 12 4 parameter model Table 2 Parameters of the 4 parameter model<br />
where the damping coefficients <strong>and</strong> the damper stiffnesses are taken into account according to the<br />
experiments for every frequency. According to Fig. 9 the damping coefficients were reduced to<br />
87 % in the horizontal direction <strong>and</strong> to 60 % in the vertical direction. The parameters of the<br />
4 parameter model are shown in Table 2.<br />
4.2 The procedure of the response analysis<br />
With the help of a three dimensional frequency response analysis program <strong>and</strong> a three<br />
dimensional time history response analysis program the response analysis was done as follows.<br />
(1) The <strong>spring</strong> rates of the <strong>spring</strong> unit were assumed to be linear. In this way the three dimensional<br />
frequency response analysis program was run. Next, the three dimensional time history response<br />
analysis program was run. Then the similarity of the two wave forms gained from the two analysis<br />
was compared.<br />
(2) The <strong>spring</strong> was modeled as a combination of a vertical <strong>spring</strong> element <strong>and</strong> a multi <strong>spring</strong><br />
element for the horizontal shear direction. The damper was modeled as a four parameter model as<br />
shown in Fig. 12. Then the three dimensional frequency response analysis program was run.<br />
4.3 Earthquake records used<br />
Earthquake records used in this analysis were modified from those of El Centro, Taft <strong>and</strong><br />
Hachinohe Earthquakes. The strength levels of the earthquake records were 50 kine for the<br />
horizontal NS <strong>and</strong> EW direction vectors.