STARTING UP<br />
G-13.mft MDB/S1<br />
Starting up in the vending machine<br />
Install the MDB model of the G-13.mft in vending machines with an MDB<br />
interface and the S1 model in vending machines with an appropriate S1<br />
interface:<br />
1 If necessary, install the sorting device on the coin validator (see<br />
section "Installation of the NRI sorting device ..." in this chapter).<br />
2 Disconnect the machine from the mains supply.<br />
3 Hang the coin validator in the vending machine mount using the lateral<br />
mounting studs 1 (see Fig. 3).<br />
4 Connect the coin validator to the machine using the 10-pole interface 3<br />
provided and the appropriate connecting cable (see Fig. 3).<br />
5 Reconnect the mains supply to the machine.<br />
Make sure the correct supply voltage is connected (see label).<br />
The G-13.mft as an MDB model does not fulfil the MDB specification<br />
on two counts, i.e. the specified voltage range and the electrical<br />
isolation of the communication lines.<br />
If a supply voltage of 42 V max. and electrical isolation are<br />
desirable, an MDB converter G-55.0360 can be ordered from NRI<br />
(ordering code 23627).<br />
1<br />
1<br />
2<br />
3<br />
1<br />
1 Mounting studs<br />
(not illustrated on the left-hand side of the device)<br />
2 Interface –<br />
PC programming station (WinEMP)/<br />
Palm handheld (PalmEMP2)<br />
3 Interface – vending machine<br />
Fig. 3: Installation<br />
26 <strong>National</strong> <strong>Rejectors</strong>, <strong>Inc</strong>. <strong>GmbH</strong>, Buxtehude