5-2 PLL ADJUSTMENTS<br />

ADJUSTMENT<br />

30.2 MHz<br />

LEVEL<br />

REFERENCE<br />

FREQUENCY<br />

144M LOCK<br />

VOLTAGE<br />

440M LOCK<br />

VOLTAGE<br />

MAIN BFO<br />

LEVEL<br />

SUB BFO<br />

LEVEL<br />

1<br />

1<br />

2<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

1<br />

2<br />

ADJUSTMENT CONDITION<br />

• Display frequency: Any<br />

• Receiving<br />

• Display frequency: Any<br />

• Receiving<br />

This adjustment must be performed<br />

at 5 minutes later after power ON.<br />

• Display frequency: 173.9800 MHz<br />

• Mode<br />

: USB<br />

• Receiving<br />

• Display frequency: 136.0200 MHz<br />

• Receiving<br />

• Display frequency: 155.0000 MHz<br />

• Receiving<br />

• Display frequency: 479.9800 MHz<br />

• Mode<br />

: USB<br />

• Receiving<br />

• Display frequency: 420.0200 MHz<br />

• Receiving<br />

• Display frequency: 450.0000 MHz<br />

• Receiving<br />

• Display frequency: Any<br />

• Mode<br />

:USB<br />

• Receiving<br />

• Sub display freq. : Any<br />

• Mode<br />

:USB<br />

• Receiving<br />

ADJUSTMENT<br />

MEASUREMENT<br />

VALUE<br />

POINT<br />

UNIT LOCATION UNIT ADJUST<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

Connect an RF voltmeter<br />

or spectram<br />

analyzer to check<br />

point J541.<br />

Connect an RF voltmeter<br />

or spectram<br />

analyzer to check<br />

point P551.<br />

Connect a frequency<br />

counter to check<br />

point P551.<br />

Connect a digital<br />

multimeter or oscilloscope<br />

to check point<br />

CP100.<br />

Connect an RF voltmeter<br />

to check point<br />

P251.<br />

Connect a digital<br />

multimeter or oscilloscope<br />

to check point<br />

CP300.<br />

Connect an RF voltmeter<br />

to check point<br />

P421.<br />

Connect an RF voltmeter<br />

to check point<br />

P601.<br />

Connect an RF voltmeter<br />

to check point<br />

P701.<br />

–10 dBm (or more than<br />

–11.5 dBm, when R570<br />

is in maximum position.)<br />

Maximum level<br />

(–13 dBm to –7dBm)<br />

60.400000 MHz<br />

2.7 V<br />

0.6 V to 1.6 V<br />

–10 dBm to –4 dBm<br />

3.4 V<br />

0.5 V to 1.5 V<br />

–16 dBm to –10 dBm<br />

–11 dBm to –5 dBm<br />

–11 dBm to –5 dBm<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

PLL<br />

R570<br />

Adjust in<br />

sequence<br />

L551, L552<br />

several<br />

times.<br />

The trimmer<br />

capacitor of<br />

X512.<br />

L193<br />

Verify<br />

Verify<br />

C402<br />

Verify<br />

Verify<br />

Verify<br />

Verify<br />

5-3 FREQUENCY ADJUSTMENT<br />

ADJUSTMENT<br />

FM TX-LO<br />

FREQUENCY<br />

ADJUSTMENT CONDITION<br />

1 • Display frequency: Any<br />

• Mode<br />

: FM<br />

• Disconnect P501, P502 (PA unit)<br />

from J51 and J52 on the MAIN unit.<br />

• Apply no audio signals to [M<strong>IC</strong>]<br />

connector.<br />

• Transmitting<br />

ADJUSTMENT<br />

MEASUREMENT<br />

VALUE<br />

POINT<br />

UNIT LOCATION UNIT ADJUST<br />

MAIN<br />

Connect a frequency<br />

counter to check<br />

point CP51.<br />

After adjustment, connect P501, P502 (PA unit) to J51, J52 on the MAIN.<br />

10.85000 MHz MAIN L255<br />

5 - 2