UX-910 ADJUSTMENTS (continued)<br />
ADJUSTMENT<br />
APC<br />
(POWER SET)<br />
1<br />
2<br />
3<br />
4<br />
5<br />
ADJUSTMENT CONDITION<br />
• Display frequency: 1270.0000 MHz<br />
• Mode<br />
: CW<br />
• Connect an SSG to the check point<br />
CP311 and set as :<br />
Frequency : 10.8500 MHz<br />
• Transmitting<br />
• Transmitting<br />
• Transmitting<br />
• Transmitting<br />
• Transmitting<br />
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.<br />
ADJUSTMENT<br />
MEASUREMENT<br />
VALUE<br />
POINT<br />
UNIT LOCATION UNIT ADJUST<br />
Rear<br />
panel<br />
MAIN<br />
(UX-910)<br />
Rear<br />
panel<br />
MAIN<br />
(UX-910)<br />
Connect an RF<br />
power meter to [12<br />
ANT].<br />
Connect a digital<br />
multimeter or oscilloscope<br />
to check point<br />
CP15.<br />
Connect an RF<br />
power meter to [12<br />
ANT].<br />
Connect a digital<br />
multimeter or oscilloscope<br />
to check point<br />
CP401.<br />
Connect a digital<br />
multimeter or oscilloscope<br />
to check point<br />
CP15.<br />
13 W<br />
3.0 V<br />
10.5 W<br />
3.1 V<br />
3.0 V<br />
MAIN<br />
(UX-910)<br />
MAIN<br />
(UX-910)<br />
MAIN<br />
(UX-910)<br />
Adjust<br />
SSG’s<br />
level<br />
R37<br />
Adjust<br />
SSG’s<br />
level<br />
R67<br />
R61<br />
5 - 20