Functions<br />
Indoor Unit<br />
Operation ON/OFF by Remote controller<br />
Sensing the <strong>Room</strong> Temperature<br />
• <strong>Room</strong> temperature sensor. (Thermistor)<br />
• Pipe temperature sensor. (Thermistor)<br />
<strong>Room</strong> temperature control<br />
• Maintain the room temperature in accordance with the Setting Temp.<br />
Starting the Current Control<br />
• Indoor fan is delayed for 5 sec at the starting.<br />
Time Delay Safety Control<br />
• Restarting is for approx. 2 minutes.<br />
Indoor Fan Speed Control<br />
• Super High, High, Med, Low<br />
Operation indication Lamps (LED)<br />
PLASMA<br />
--- Lights up in operation<br />
--- Lights up in Sleep Mode<br />
--- Lights up in Timer Mode<br />
--- Lights up in Preheat Mode (for Heating Model)<br />
--- Lights up in Plasma <strong>Air</strong> Clean Mode<br />
Soft Dry Operation Mode<br />
• Intermittent Operation of fan at low speed or off.<br />
Sleep Mode Auto Control<br />
• The fan is switched to low(Cooling), low(Heating) speed.<br />
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.<br />
Natural <strong>Air</strong> Control by CHAOS Logic<br />
• The fan is switched to intermittent or irregular operation<br />
• The fan speed is automatically switched from high to low speed.<br />
<strong>Air</strong>flow Direction Control<br />
• The louver can be set at the desired position or swing<br />
up and down automatically.<br />
Auto Changeover<br />
AUTO CLEAN(Optional)<br />
PLASMA<br />
Functions<br />
• The function will be operated while in any<br />
operation mode with selecting the function.<br />
• The function is to be stopped while it is<br />
operating with selecting the function.<br />
Defrost(Deice) control (Heating)<br />
• Both the indoor and outdoor fan stops<br />
during defrosting.<br />
Hot-start Control (Heating)<br />
• The indoor fan stops until the<br />
evaporator pipe temperature will be<br />
reached at 34°C.<br />
Heater (Optional)<br />