Troubleshooting Guide<br />
Trouble 6<br />
72 <strong>Room</strong> <strong>Air</strong> <strong>Conditioner</strong><br />
The heater does not operate at all.<br />
Turn off main power<br />
Check the wire connection of PTC Heater (Refer to Wiring Diagram)<br />
• Check the connecting condition of CN-PTC connector on the indor DC P.C.B Ass'y.<br />
• Check the soldering condition of CN-PTC connector on the indoor DC P.C.B Ass'y.<br />
Check the Heater driving Circuit.<br />
• Check the pattern between MICOM Pin No. 48 → IC02M Pin No. 7 → IC02M Pin No. 10 → CN-PTC<br />
If there is no problem result of all above check.<br />
• Inner side disconnection of PTC Heater unit or restriced operating condition of PTC Heater<br />
(pipe temp. is over 45°C, defrosting operation, compressor off, indoor fan off).