■ The problem of missing the connector (INDOOR MAIN PCB ASSY)<br />

Connectors<br />

CN-AC/DC<br />

CN-FAN<br />

CN-T/Block<br />

CN-DISP1<br />

CN-DISP2<br />

CN-TH<br />

CN-U/D<br />

Condition<br />

OPEN<br />

OPEN<br />

OPEN<br />

OPEN<br />

OPEN<br />

OPEN/SHORT<br />

OPEN<br />

■ The problem of missing the connector (OUTDOOR MAIN PCB ASSY)<br />

Connectors Condition<br />

CN-4 WAY<br />

CN-FAN<br />

CN-TH<br />

CN-D-PIPE<br />

CN-UVW<br />

OPEN<br />

OPEN<br />

OPEN/SHORT<br />

OPEN/SHORT<br />

OPEN<br />

Problem (error mode)<br />

• Malfunctions all indoor & outdoor unit.<br />

• Malfunctions remocon, force, test operation mode.<br />

• Malfunctions indoor fan motor.<br />

• Malfunctions outdoor unit.<br />

• Stop compressor and outdoor fan motor.<br />

• The operation LED blinks 5 times.<br />

• Communication error.<br />

• Malfunctions remote contoller.<br />

• Don't operate the power display module.<br />

• Don't operate the power display module.<br />

• The operation LED blinks twice.<br />

• Enable to receive remote singnal.<br />

• Malfunctions UP/DOWN step motor.<br />

• Don't operate louver.<br />

• Malfunctions 4-WAY valve.<br />

• Malfunctions fan<br />

• Stop compressor.<br />

Problem (error mode)<br />

• The operation LED blinks twice.<br />

• The LED01M blinks twice.<br />

• The LED01M blinks 10 times.<br />

• Continue Comp. operation.<br />

(when the discharge pipe TH opens)<br />

• Stop Comp. operation<br />

(when the discharge pipe TH shorts)<br />

Troubleshooting Guide<br />