Trouble 7<br />

The Outdoor Unit does not operate at all.<br />

Does the Operating LED of indoor unit blink<br />

when Operation's ON?<br />

NO<br />

Is the Connection between indoor power<br />

relay Pin ➂ and terminal block No. 1 right?<br />

YES<br />

Is the connection of cable between indoor<br />

and outdoor unit right?<br />

YES<br />

Is the voltage of Terminal Block , in<br />

outdoor Control Box about AC220V /<br />

240V?<br />

YES<br />

Is the voltage of NF01J ➀, ➁ in outdoor<br />

PCB Ass'y about AC220V / 240V when<br />

Operation's ON?<br />

YES<br />

NO<br />

NO<br />

NO<br />

NO<br />

Refer to the self-diagnosis function.<br />

Check the connecting state of connector<br />

Indoor Outdoor<br />

1(Brown) 1(Brown)<br />

2(Blue) 2(Blue)<br />

3(Green/YL) 3(Green/YL)<br />

4(Red) 4(Red)<br />

Check the Fuse of Outdoor PCB Ass'y.<br />

Check the PTC and RY-PWR.<br />

Is the Bridge Diode(BD01S) right? Check the Bring Diode.<br />