Protection of the evaporator pipe from frosting<br />
Operation<br />
• If the indoor pipe temperaure is below 0°C in 7 min. after the compressor operates without pause while in<br />
cooling cycle operation mode,<br />
➔ compressor, outdoor fan are turned off.<br />
• When indoor pipe temp. is 7°C or higher after 2 min pause of compressor<br />
➔ compressor, outdoor fan is turned on according to the condition of the room temperature.<br />
Comp. free<br />
Indoor pipe<br />
temp.<br />
6˚ C<br />
3˚ C<br />
0˚ C<br />
Comp. Step 4<br />
Comp. Step 2<br />
Comp. off<br />
7˚ C<br />
Protection of the indoor fan from droplet formation (Enclosure sweat and condensed disposal test)<br />
• Control condition : The system operates standard operation without this condition as follows.<br />
Setting temperature