LG Room Air Conditioner - Hawco
LG Room Air Conditioner - Hawco
LG Room Air Conditioner - Hawco
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Troubleshooting Guide<br />
Trouble 4<br />
70 <strong>Room</strong> <strong>Air</strong> <strong>Conditioner</strong><br />
When indoor Fan does not operate.<br />
Turn off main power.<br />
Check the connection of CN-MOTOR.<br />
Check the Fan Motor.<br />
Check the Fuse(AC250V, T2A).<br />
Check the related circuit of indoor Fan Motor.<br />
• The pin No.45 of micom and the part for driving SSR.<br />
• Check the related pattern.<br />
• Check the SSR.<br />
- SSR Open: Indoor Fan Motor never operate.<br />
- SSR short: Indoor Fan Motor always operates in case of ON or OFF.<br />
Turn on the main power<br />
Check the SSR high speed operation by remote control.<br />
(the Indoor Fan Motor is connected)<br />
The voltage of Pin No 1(orange) and 3(black) of CN-MOTOR.<br />
About AC 180V over About AC 50V over<br />
SSR is not damaged Check SSR