water and sanitation concession agreement - example 1 annexures ...
water and sanitation concession agreement - example 1 annexures ...
water and sanitation concession agreement - example 1 annexures ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SEPTIC TANK<br />
Septic Tank / VIP (ventilated improved pit latrine) clearance by sucker truck - [AMOUNT AND CURRENCY] (adequate vehicular<br />
access must be provided by the user for this service to be provided). Call out charge of [AMOUNT AND CURRENCY] will be levied<br />
should vehicular access not be adequate.<br />
RECEIPT OF SEWAGE<br />
For receipt of sewage transported by tanks other than in 6 above - [AMOUNT AND CURRENCY] per kilolitre.<br />
DISCHARGE OF “WET” INDUSTRIAL EFFLUENT<br />
(Industries which use or generate a considerable quantity of <strong>water</strong>)<br />
The owner of or occupier of premises on which any trade or industry identified by the Concessionaire as a “wet” trade or industry, is<br />
carried out <strong>and</strong> from which as a result of such trade or industry or of any process incidental thereto, any effluent is discharged into the<br />
sewer, shall in addition to the fixed Charges set out in table 1.2.1 for which he is liable in terms of this determination, pay to the<br />
Concessionaire in place of the variable Charges set out in table 1.2.2 an amount calculated on the quantity of <strong>water</strong> consumed during<br />
the period <strong>and</strong> in accordance with the Treatment Charge Formula <strong>and</strong> the Disincentive Formula set out hereunder -<br />
Treatment Charge Formula<br />
To = C(Q i )/(Qt)(0,31 + 0,22Kc + 0,27Ks +0,20Kn)<br />
Where<br />
To = Charges due by an individual contributor<br />
C = Total capital redemption, interest, operation <strong>and</strong> maintenance cost of the sewage treatment works set by the<br />
Concessionaire<br />
Qi = Sewage flow from an individual contributor (megalitre per day)<br />
Qt = Total sewage flow in the system (megalitre per day)<br />
Kc = COD i /COD t<br />
Ks = SSi/SSt<br />
Kn = Ni/Nt<br />
COD i = Chemical oxygen dem<strong>and</strong> of the settled sewage originating from the contributor (milligrams per litre)<br />
40<br />
PPP in Infrastructure Resource Center for Contracts, Laws <strong>and</strong> Regulations (PPPIRC)<br />
Reviewed: Victoria R. Delmon, LEGPS<br />
http://www.worldbank.org/ppp November 2007