3. TROUBLESHOOTING AND ACTION TO BE TAKEN<br />

B–<strong>62075E</strong>/<strong>03</strong><br />

3.2.3 Lighting of alarm LEDs on PCBs<br />

If an alarm condition occurs, an alarm message is usually displayed on the CRT screen. The state of the PCB<br />

when the alarm occurred is indicated by the LEDs on the front panel of each control unit PCBs, as shown below.<br />

When a system alarm occurs, the alarm message displayed on the screen, together with the LED indications<br />

on each PCB, help you to determine the cause. Record the LED indications for each PCB to enable rapid recovery<br />

of the system.<br />

For the descriptions of LED lamps on each printed circuit board, see Chapter 7.<br />

STATUS<br />

ALARM<br />

1 2 3 4<br />

<br />

<br />

<br />

<br />

<br />

Fig. 3.2.3 LED Display for the Printed Circuit Boards in the Control Unit<br />

– 22 –